The DOI matches its Crossref record.
Determination of Major/ Minor and Trace Elements in Silicate Samples by ICP‐QMS and ICP‐SFMS Applying Isotope Dilution‐Internal Standardisation (ID‐IS) and Multi‐Stage Internal Standardisation
Abstract
A method for the determination of major, minor and trace elements in silicate samples by ICP‐QMS and ICP‐SFMS applying isotope dilution‐internal standardisation (ID‐IS) and multi‐stage internal standardisation has been developed. Samples with an enriched isotope of 149 Sm (spike) were decomposed by a HF/HCIO 4 mixture and stepwise drying and finally diluted. In ID‐IS for trace element analyses by Q‐pole type ICP‐MS (ICP‐QMS), the Sm concentration was determined by ID, while other trace elements (Li, Be, Rb, Sr, Y, In, Cs, Ba, La, Ce, Pr, Nd, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Tl, Pb, Bi, Th and U) were determined using the 149 Sm intensity as an internal standard. Major and minor elements were determined by multi‐stage internal standardisation, with Na, Mg, Al, P, Ca, V, Mn, Fe and Co measured by sector magnetic field type ICP‐MS (ICP‐SFMS) at middle resolution (MR; M/AM =∼ 3000) using Sr determined by ICP‐QMS in the sample as the internal standard. Potassium, Sc, Ni, Cu, Zn and Ga were measured at high resolution (HR; M/ΔM ∼ 7500) using the Sr concentration obtained by ICP‐QMS or the Mn concentration obtained by ICP‐SFMS at MR as internal standard. The merit of ID‐IS is that accurate dilution of the sample is not required. Matrix effects on elemental ratios down to a dilution factor (DF) of 600 were not observed in either types of mass spectrometry. Pseudo‐flow injection (FI), where transient signals were integrated, was used in ICP‐QMS, while conventional continuous sample introduction was used in ICP‐SFMS, resulting in total required sample solutions of 0.026 ml and 0.08 ml, respectively. Detection limits were low enough to determine these elements in depleted ultramafic rocks, and typical reproducibilities for basalts were 3% (Li‐Be), 1% (Rb‐U), 5% (In, Tl and Bi), 7% (Sc‐Ga) and 3% (major elements). Carbonaceous chondrites including Orgueil (Cll), Murchison (CM2) and Allende (CV3), as well as reference materials, JB‐1, ‐2, ‐3, JA‐1, ‐2, ‐3 and JP‐1 (GSJ), BHVO‐1, AGV‐1, PCC‐1 and DTS‐1 (USGS), were analysed to show the applicability of this method. Une méthode permettant la détermination des éléments majeurs, mineurs et en trace dans les echantillons silicates par ICP‐QMS et ICP‐SFMS a été développée. Elle combine la standardisation interne par dilution isotopique (ID‐IS) et la standardisation interne en deux étapes. Les échantillons, auxquels est ajouté un spike enrichi en 149 Sm, sont décomposés par une mixture HF/HCIO 4′ séchés progressivement puis dilués. Dans la phase de standardisation interne par dilution isotopique avec un ICP‐MS à quadrupôle (ICP‐QMS), la concentration en Sm est déterminée par dilution isotopique tandis que les autres éléments en trace (Li, Be, Rb, Sr, Y, In, Cs, Ba, La, Ce, Pr, Nd, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Tl, Pb, Bi, Th et U) sont déterminés en utilisant le signal de 149 Sm comme standard interne. Les éléments majeurs et mineurs sont déterminés par standardisation interne par étapes, avec Na, Mg, Al, P, Ca, V, Mn, Fe et Co mesurés par ICP‐MS à secteur magnétique (ICP‐SFMS) en résolution intermédiaire (MR; M/Δ M =∼ 3000 en utilisant Sr, mesuré par ICP‐QMS comme standard interne. Les éléments K, Sc, Ni, Cu, Zn et Ga sont mesurés en Haute Résolution (M/Δ M ∼ 7500) en utilisant comme standard interne, soit la concentration en Sr obtenue par ICP‐QMS soit la concentration en Mn obtenue par ICP‐SFMS en résolution moyenne. La technique de ID‐IS a l'avantage de ne pas nécessiter la connaissance exacte du facteur de dilution de l'Schantillon. Aucun effet de matrice sur la mesure de rapports élémentaires n'a été observé sur l'un ou l'autre des spectromètres de masse, ceci jusqu'à un facteur de dilution (DF) de 600. Les analyses par ICP‐QMS ont été effectuées par pseudo injection de flux (Fl) et intégration d'un signal transitoire tandis que les analyses par ICP‐SFMS l'ont été avec un système conventionnel d'introduction. Le volume total de solution d'échantillon nécessaire etait de 0.026 ml et 0.08 ml respectivement. Les limites de détection étaient suffisamment basses pour permettre la détermination de ces éléments dans des roches ultrabasiques et les reproductibilités pour les basaltes étaient de l'ordre de 3% (Li‐Be), 1 % (Rb‐U), 5% (In, Tl et Bi), 7% (Sc‐Ga) et 3% (tous les éléments majeurs). Des chondrites carbonées dont Orgueil (Cll), Murchison (CM2) et Allende (CV3) ainsi que des matériaux de référence JB‐1, ‐2, ‐3, JA‐1, ‐2, ‐3 et JP‐1 (GSJ), BHVO‐1, AGV‐1, PCC‐1 et DTS (USGS) ont été analysés pour démontrer l'applicabilité de la méthode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
4.4 Abundances of the elements in the Solar System
Lodders, K., Palme, H., & Gail, H.-P. (2009) · Landolt-Börnstein - Group VI Astronomy and Astrophysics · doi:10.1007/978-3-540-88055-4_34 · Cited by 527
Pourmand, A., Dauphas, N., & Ireland, T. J. (2012) · Chemical Geology · doi:10.1016/j.chemgeo.2011.08.011 · Cited by 513
Geochemistry of CI chondrites: Major and trace elements, and Cu and Zn Isotopes
Barrat, J. A., Zanda, B., Moynier, F., Bollinger, C., Liorzou, C., & Bayon, G. (2012) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2011.12.011 · Cited by 428
Solar System Abundances of the Elements
Lodders, K. (2010) · Astrophysics and Space Science Proceedings · doi:10.1007/978-3-642-10352-0_8 · Cited by 348
Solar System Abundances of the Elements
Palme, H., Lodders, K., & Jones, A. (2014) · Treatise on Geochemistry · doi:10.1016/b978-0-08-095975-7.00118-2 · Cited by 329
Metadata
- Authors
- Makishima, A., & Nakamura, E.
- Venue
- Geostandards and Geoanalytical Research
- Publisher
- Wiley
- Published
- 2006-11
- Volume
- 30
- Issue
- 3
- Pages
- 245-271
- ISSN
- 0150-5505 (ISSN-L)
- 1639-4488
- 1751-908X
- OpenAlex
- W2080609618
- Cited by
- 175
- References
- 0
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Major/ Minor and Trace Elements in Silicate Samples by ICP‐QMS and ICP‐SFMS Applying Isotope Dilution‐Internal Standardisation (ID‐IS) and Multi‐Stage Internal Standardisation. https://app.cochat.ai/papers/10.1111/j.1751-908x.2006.tb01066.x
- The paper
- Makishima, A., & Nakamura, E. (2006). Determination of Major/ Minor and Trace Elements in Silicate Samples by ICP‐QMS and ICP‐SFMS Applying Isotope Dilution‐Internal Standardisation (ID‐IS) and Multi‐Stage Internal Standardisation. Geostandards and Geoanalytical Research. https://doi.org/10.1111/j.1751-908x.2006.tb01066.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.