The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Detection of Congestive Heart Failure in Dogs by Doppler Echocardiography
Open accessAbstract
Background: Echocardiographic prediction of congestive heart failure (CHF) in dogs has not been prospectively evaluated. Hypothesis: CHF can be predicted by Doppler echocardiographic (DE) variables of left ventricular (LV) filling in dogs with degenerative mitral valve disease (MVD) and dilated cardiomyopathy (DCM). Animals: Sixty-three client-owned dogs. Methods: Prospective clinical cohort study. Physical examination, thoracic radiography, analysis of natriuretic peptides, and transthoracic echocardiography were performed. Diagnosis of CHF was based upon clinical and radiographic findings. Presence or absence of CHF was predicted using receiver-operating characteristic (ROC) curve, multivariate logistic and stepwise regression, and best subsets analyses. Results: Presence of CHF secondary to MVD or DCM could best be predicted by E : isovolumic relaxation time (IVRT) (area under the ROC curve [AUC]=0.97, P < .001), respiration rate (AUC=0.94, P < .001), Diastolic Functional Class (AUC=0.93, P < .001), and a combination of Diastolic Functional Class, IVRT, and respiration rate (R2=0.80, P < .001) or Diastolic Functional Class (AUC=1.00, P < .001), respiration rate (AUC=1.00, P < .001), and E : IVRT (AUC=0.99, P < .001), and a combination of Diastolic Functional Class and E : IVRT (R2=0.94, P < .001), respectively, whereas other variables including N-terminal pro-brain natriuretic peptide, E : Ea, and E : Vp were less useful. Conclusion and Clinical Importance: Various DE variables can be used to predict CHF in dogs with MVD and DCM. Determination of the clinical benefit of such variables in initiating, modulating, and assessing success of treatments for CHF needs further study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Note on the Sampling Error of the Difference Between Correlated Proportions or Percentages
McNemar, Q. (1947) · Psychometrika · doi:10.1007/bf02295996 · Cited by 4,754
Cited by
Keene, B. W., Atkins, C. E., Bonagura, J. D., Fox, P. R., Häggström, J., Fuentes, V. L., Oyama, M. A., Rush, J. E., Stepien, R., & Uechi, M. (2019) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.15488 · Cited by 831
Self-citation
Metadata
- Authors
- Schober, K. E., Hart, T. M., Stern, J. A., Li, X., Samii, V. F., Zekas, L. J., Scansen, B. A., & Bonagura, J. D.
- Venue
- Journal of Veterinary Internal Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-11-01
- Volume
- 24
- Issue
- 6
- Pages
- 1358-1368
- ISSN
- 0891-6640 (ISSN-L)
- 1939-1676
- OpenAlex
- W1581536049
- Cited by
- 175
- References
- 2
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Congestive Heart Failure in Dogs by Doppler Echocardiography. https://app.cochat.ai/papers/10.1111/j.1939-1676.2010.0592.x
- The paper
- Schober, K. E., Hart, T. M., Stern, J. A., Li, X., Samii, V. F., Zekas, L. J., Scansen, B. A., & Bonagura, J. D. (2010). Detection of Congestive Heart Failure in Dogs by Doppler Echocardiography. Journal of Veterinary Internal Medicine. https://doi.org/10.1111/j.1939-1676.2010.0592.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.