The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Drug-delivery Products and the Zydis Fast-dissolving Dosage Form
Abstract
Many patients find it difficult to swallow tablets and hard gelatin capsules and do not take their medication as prescribed. It is estimated that 50% of the population is affected by this problem which results in a high incidence of non-compliance and ineffective therapy. The difficulty is experienced in particular by paediatric and geriatric patients, but it also applies to people who are ill in bed and to those active working patients who are busy or travelling, especially those who have no access to water. Such problems can be resolved by means of the Zydis dosage form which does not require water to aid swallowing. The Zydis fast-dissolving dosage form is a unique freeze dried medicinal tablet, made from well known and acceptable materials. When Zydis units are put into the mouth, the freeze dried structure disintegrates instantaneously releasing the drug which dissolves or disperses in the saliva. The saliva containing the dissolved or dispersed medicament is then swallowed and the drug is absorbed in the normal way. Some drugs are absorbed from the mouth, pharynx and oesophagus as the saliva passes down into the stomach. In these cases, the bioavailabilities of drugs from Zydis formulations are significantly greater than those observed from standard dosage forms. This paper deals with the formulation and process technology of the Zydis dosage form. The bioavailability characteristics of Zydis products are summarized, and in particular, the design of Zydis products for the enhancement of oral bioavailability and the improvement of clinical activity, through transmucosal delivery and pregastric absorption, is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The behaviour of a fast-dissolving dosage form (Expidet) followed by γ-scintigraphy
WILSON, C. G., Washington, N., Peach, J. M., Murray, G. R., & Kennerley, J. R. (1987) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(87)90056-1 · Cited by 71
Cited by
Lu, Y., Aimetti, A. A., Langer, R., & Gu, Z. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.75 · Cited by 1,421
Zhang, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.009 · Cited by 462
Li, X., Kanjwal, M. A., Lin, L., & Chronakis, I. S. (2013) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2012.10.016 · Cited by 318
Orally Disintegrating Tablets: A Review
Hirani, J. J., Rathod, D., & Vadalia, K. (2009) · Tropical Journal of Pharmaceutical Research · doi:10.4314/tjpr.v8i2.44525 · Cited by 272
Formulation approaches in enhancement of patient compliance to oral drug therapy
Shahiwala, A. (2011) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2011.628311 · Cited by 84
Metadata
- Authors
- Seager, H.
- Venue
- Journal of Pharmacy and Pharmacology
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-04-01
- Volume
- 50
- Issue
- 4
- Pages
- 375-382
- ISSN
- 0022-3573 (ISSN-L)
- 2042-7158
- OpenAlex
- W2047846970
- Cited by
- 581
- References
- 1
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Drug-delivery Products and the Zydis Fast-dissolving Dosage Form. https://app.cochat.ai/papers/10.1111/j.2042-7158.1998.tb06876.x
- The paper
- Seager, H. (1998). Drug-delivery Products and the Zydis Fast-dissolving Dosage Form. Journal of Pharmacy and Pharmacology. https://doi.org/10.1111/j.2042-7158.1998.tb06876.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.