Overcoming sink limitations in dissolution testing: a review of traditional methods and the potential utility of biphasic systems
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Objectives: The conventional dissolution test, particularly the USP apparatus I and II, remains an important tool in the armory of the pharmaceutical development scientist. For realistic dissolution characterization, sink conditions, where saturation solubility of a drug in the dissolution medium is at least three times more than the drug concentration, are critical. These conditions can be problematic to maintain with formulations containing poorly-soluble actives. This review summarizes the role of the dissolution test in the pharmaceutical industry, together with some traditional techniques/additives used to enhance solubility and facilitate the achievement of sink conditions. The biphasic dissolution system, an innovative model for the treatment of poorly-soluble species, will also be discussed. Key findings: The biphasic dissolution model utilizes media comprising immiscible aqueous and organic layers whereby the drug, following initial aqueous dissolution, partitions into the organic layer. This step, which acts to remove all dissolved species from the aqueous layer, enables further aqueous dissolution to occur and hence the dissolution–partition cycle continues. Crucially, the aqueous layer does not saturate allowing sink conditions to be maintained and hence the experiment will, in theory, yield complete dissolution. Summary: This review highlights important concepts regarding solubility/sink limitation and intends to provoke debate among analytical and formulation scientists as to the potential advantages, long-term development and widespread implementation of a biphasic dissolution system in drug development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amidon, G. L., Lennernäs, H., Shah, V. P., & Crison, J. R. (1995) · Pharmaceutical Research · doi:10.1023/a:1016212804288 · Cited by 5,430 · cited 3×
“In 1995 Amidon et al. proposed the classification of drugs on the basis of aqueous solubility and intestinal permeability.”
MethodInfluentialTHE RATE OF SOLUTION OF SOLID SUBSTANCES IN THEIR OWN SOLUTIONS.
Noyes, A. A., & Whitney, W. R. (1897) · Journal of the American Chemical Society · doi:10.1021/ja02086a003 · Cited by 1,884
Encyclopedia of Pharmaceutical Technology
Swarbrick, J. (2013) · CRC Press eBooks · doi:10.1201/b19309 · Cited by 1,794
Solubilizing Excipients in Oral and Injectable Formulations
Strickley, R. G. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000016235.32639.23 · Cited by 1,415 · cited 1×
“Co-solvents are useful if the molecule contains no ionizable groups and cannot be solubilized by adjusting the pH of the dissolution medium.([38]) As illustrated in Equation 1, solubility typically increases logarithmically with a linear increase in the fraction of organic solvent, where Cs and Co are the drug solubil…”
BackgroundPouton, C. W. (2006) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2006.04.016 · Cited by 1,293 · cited 1×
“Investigation of the application to poorly permeable drugs (BCS Classes III and IV) may prove interesting as the potentially limited partitioning ability of such drugs following aqueous dissolution may pose analytical issues.([75]) The ability to develop rigorous and routine IVIVCs using the model would be beneficial…”
BackgroundDissolution Testing as a Prognostic Tool for Oral Drug Absorption: Immediate Release Dosage Forms
Dressman, J. B., Amidon, G. L., Reppas, C., & Shah, V. P. (1998) · Pharmaceutical Research · doi:10.1023/a:1011984216775 · Cited by 1,097 · cited 1×
“Clearly this places significant importance on the dissolution test in the drug development process, particularly in product development where it can be used to (i) assist with formulation development and comparison([2,3]) and (ii) relate in-vitro and in-vivo performance.([4]) A simple and efficient tool of analysis, i…”
MethodEvaluation of Various Dissolution Media for Predicting In Vivo Performance of Class I and II Drugs
Galia, E., Nicolaides, E., Hörter, D., Löbenberg, R., Reppas, C., & Dressman, J. B. (1998) · Pharmaceutical Research · doi:10.1023/a:1011910801212 · Cited by 927 · cited 1×
“Future work should focus on the application to other drug classes, though the model may not hold the same value for the testing of highly soluble drugs (BCS Class I) where sink conditions are easily achieved.([74]) Investigation of the application to poorly permeable drugs (BCS Classes III and IV) may prove interestin…”
BackgroundLindenberg, M., Kopp, S., & Dressman, J. B. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.001 · Cited by 864 · cited 1×
“Classified as a BCS Class II drug,([65]) it has a low aqueous solubility that remains approximately constant across the pH range 2–13 (a 0.”
BackgroundDokoumetzidis, A., & Macheras, P. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2006.07.011 · Cited by 715 · cited 1×
“In 1970, the basket-stirred-flask test (USP, apparatus I) was adopted as an official dissolution test in six monographs of the USP and National Formulary (NF).([9]) Subsequent developments led to the USP adopting other apparatus fit for the analysis of several dosage forms (Table 1).”
MethodBiopharmaceutics Classification System: The Scientific Basis for Biowaiver Extensions
Yu, L. X., Amidon, G. L., Polli, J. E., Zhao, H., Mehta, M. U., Conner, D. P., Shah, V. P., Lesko, L. J., Chen, M.-L., Lee, V. H. L., et al. (2002) · Pharmaceutical Research · doi:10.1023/a:1016473601633 · Cited by 571 · cited 1×
“If greater than 250 ml is required to dissolve the drug, or absorption is less than 90%, it is considered to be poorly soluble or poorly permeable, respectively.([14]) Modern drug discovery processes appear to be unearthing an increasing number of compounds with poor aqueous solubility.”
Background
Cited by
Boyd, B. J., Bergström, C. A. S., Vinarov, Z., Kuentz, M., Brouwers, J., Augustijns, P., Brandl, M., Bernkop-Schnürch, A., Shrestha, N., Préat, V., et al. (2019) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2019.104967 · Cited by 367
Release Kinetics Study of Poorly Water-Soluble Drugs from Nanoparticles: Are We Doing It Right?
Abouelmagd, S. A., Sun, B., Chang, A. C., Ku, Y. J., & Yeo, Y. (2015) · Molecular Pharmaceutics · doi:10.1021/mp500817h · Cited by 259
de Andrade, D. F., Zuglianello, C., Pohlmann, A. R., Guterres, S. S., & Beck, R. C. R. (2015) · AAPS PharmSciTech · doi:10.1208/s12249-015-0330-0 · Cited by 43
Metadata
- Authors
- Phillips, D. J., Pygall, S. R., Cooper, V. B., & Mann, J. C.
- Venue
- Journal of Pharmacy and Pharmacology
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-11-01
- Volume
- 64
- Issue
- 11
- Pages
- 1549-1559
- ISSN
- 0022-3573 (ISSN-L)
- 2042-7158
- OpenAlex
- W1900239988
- Cited by
- 213
- References
- 29
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.