Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 165

The DOI matches its Crossref record.

A Novel Electrocardiographic Criterion for Differentiating a Left from Right Ventricular Outflow Tract Tachycardia Origin: The V2S/V3R Index

YOSHIDA, NAOKI, YAMADA, TAKUMI, MCELDERRY, H. THOMAS, INDEN, YASUYA, SHIMANO, MASAYUKI, MUROHARA, TOYOAKI, KUMAR, VINEET, DOPPALAPUDI, HARISH, PLUMB, VANCE J., KAY, G. NEAL · 2014 · Journal of Cardiovascular Electrophysiology

Abstract

V2S/V3R Index Distinguishes LVOT from RVOT Origins: Introduction: Although several ECG criteria have been proposed for differentiating between left and right origins of idiopathic ventricular arrhythmias (VA) originating from the outflow tract (OT‐VA), their accuracy and usefulness remain limited. This study was undertaken to develop a more accurate and useful ECG criterion for differentiating between left and right OT‐VA origins. Methods and Results: We studied OT‐VAs with a left bundle branch block pattern and inferior axis QRS morphology in 207 patients who underwent successful catheter ablation in the right (RVOT; n = 154) or left ventricular outflow tract (LVOT; n = 53). The surface ECGs during the OT‐VAs and during sinus beats were analyzed with an electronic caliper. The V2S/V3R index was defined as the S‐wave amplitude in lead V2 divided by the R‐wave amplitude in lead V3 during the OT‐VA. The V2S/V3R index was significantly smaller for LVOT origins than RVOT origins (P < 0.001). The area under the curve (AUC) for the V2S/V3R index by a receiver operating characteristic analysis was 0.964, with a cut‐off value of ≤1.5 predicting an LVOT origin with an 89% sensitivity and 94% specificity. In the AUC and accuracy, the V2S/V3R index was superior to any previously proposed ECG criteria in an analysis of all OT‐VAs. This advantage of the V2S/V3R index over the V2 transition ratio and other indices also held true for a subanalysis of 77 OT‐VAs with a lead V3 precordial transition. Conclusion: The V2S/V3R index outperformed other ECG criteria to differentiate left from right OT‐VA origins independent of the site of the precordial transition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jce.12392

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 165

Metadata

Authors
YOSHIDA, N., YAMADA, T., MCELDERRY, H. T., INDEN, Y., SHIMANO, M., MUROHARA, T., KUMAR, V., DOPPALAPUDI, H., PLUMB, V. J., & KAY, G. N.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2014-03-19
Volume
25
Issue
7
Pages
747-753
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2123785188
Cited by
165
References
0
FWCI
5.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Electrocardiographic Criterion for Differentiating a Left from Right Ventricular Outflow Tract Tachycardia Origin: The V2S/V3R Index. https://app.cochat.ai/papers/10.1111/jce.12392
The paper
YOSHIDA, N., YAMADA, T., MCELDERRY, H. T., INDEN, Y., SHIMANO, M., MUROHARA, T., KUMAR, V., DOPPALAPUDI, H., PLUMB, V. J., & KAY, G. N. (2014). A Novel Electrocardiographic Criterion for Differentiating a Left from Right Ventricular Outflow Tract Tachycardia Origin: The V2S/V3R Index. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.12392

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.