Cited by 22Atrial Fibrillation Management and OutcomesThyroid Disorders and TreatmentsCardiac electrophysiology and arrhythmias

Free thyroxine within the normal reference range predicts risk of atrial fibrillation

Anderson, Jeffrey L., Jacobs, Victoria, May, Heidi T., Bair, Tami L., Benowitz, Barry A., Lappe, Donald L., Muhlestein, Joseph B., Knowlton, Kirk U. +1 more·2020·Journal of Cardiovascular Electrophysiology

Abstract

Introduction: Hyperthyroidism is a known precipitating factor for atrial fibrillation (AF). However, recent reports have suggested an increased risk of AF with free thyroxine (fT4) levels even within the upper reference (normal) range. We sought to test whether higher fT4 levels within the reference range are associated with an increased risk of AF. Methods and Results: All patients in the Intermountain Healthcare electronic medical record database with an fT4 level not on thyroid medication were included. The reference range of fT4 was divided into quartiles (Q), and associations with prevalent and incident AF were assessed by multivariable regression. Similar analyses were performed for thyroid stimulating hormone (TSH) and total and free T3. A total of 174 914 patients were included and followed for 7.0 ± 4.9 years. Of these, 7.4%, 88.4%, and 4.2% had fT4 levels below, within, and above the reference range. As expected, prevalent AF was greater with elevated fT4. However, gradients also were noted within the reference range, comparing Q4 to Q1, for prevalent AF (adjusted odds ratio 1.4, P < .0001) and incident AF (adjusted hazard ratio 1.16, P < .0001). In contrast, no relationship with AF prevalence and incidence was noted for total and free T3 within their reference ranges, and the pattern for TSH was uninformative. Conclusion: Higher fT4 levels within the reference range were associated with an increased prevalence and incidence of AF. These findings in a large dataset prospectively validate earlier reports and may have important implications, including a redefinition of the normal range and fT4 targets for replacement therapy.

Integrity signals

Registry

Crossref · 10.1111/jce.14183

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In that analysis, no relationship was noted for serum total T3 and fT3 within their normal reference ranges with AF.

    “but no relationship was noted for serum total T3 and fT3 within their normal reference ranges (62).”
  • In an analysis of 174,914 patients followed for 7.0 ± 4.9 years, incidence and prevalence of AF was greater with elevated serum fT4 levels even within the normal reference range.

    “The first is an analysis of 174,914 patients followed for 7.0 ± 4.9 years. It revealed that the incidence and prevalence of AF was greater with elevated serum fT4 levels, even within the normal reference range”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Anderson, J. L., Jacobs, V., May, H. T., Bair, T. L., Benowitz, B. A., Lappe, D. L., Muhlestein, J. B., Knowlton, K. U., & Bunch, T. J.
Affiliations
  • University of Utah (US)
  • Intermountain Medical Center (US)
Corresponding author
Anderson, Jeffrey L.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2019-11-17
Volume
31
Issue
1
Pages
18-29
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2972753888
Cited by
22
References
7
Citations by year
2026: 1 · 2024: 8 · 2023: 4 · 2022: 5 · 2021: 3 · 2020: 1
FWCI
1.59
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Cardiovascular Electrophysiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
free thyroxine, atrial fibrillation, thyroid function, hyperthyroidism, thyroid-stimulating hormone, free triiodothyronine, atrial fibrillation risk, thyroid hormone replacement
MeSH terms
Aged, Atrial Fibrillation, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Reference Values, Retrospective Studies, Risk Factors, Thyroid Diseases, Thyroxine, United States, Biomarkers, Incidence, Prevalence, Databases, Factual, Electronic Health Records

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review