Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 204

The DOI matches its Crossref record.

Randomized controlled clinical study evaluating effectiveness and safety of a volume‐stable collagen matrix compared to autogenous connective tissue grafts for soft tissue augmentation at implant sites

Open access
Thoma, Daniel S., Zeltner, Marco, Hilbe, Monika, Hämmerle, Christoph H. F., Hüsler, Jürg, Jung, Ronald E.·2016·Journal of Clinical Periodontology

Abstract

Aim: To test whether or not the use of a collagen matrix (VCMX) results in short‐term soft tissue volume increase at implant sites non‐inferior to an autogenous subepithelial connective tissue graft (SCTG), and to evaluate safety and tissue integration of VCMX and SCTG. Methods: In 20 patients with a volume deficiency at single‐tooth implant sites, soft tissue volume augmentation was performed randomly allocating VCMX or SCTG. Soft tissue thickness, patient‐reported outcome measures (PROM s), and safety were assessed up to 90 days (FU‐90). At FU‐90 (abutment connection), tissue samples were obtained for histological analysis. Descriptive analysis was computed for both groups. Non‐parametric tests were applied to test non‐inferiority for the gain in soft tissue thickness at the occlusal site. Results: Median soft tissue thickness increased between BL and FU‐90 by 1.8 mm (Q1:0.5; Q3:2.0) (VCMX) (p = 0.018) and 0.5 mm (−1.0; 2.0) (SCTG) (p = 0.395) (occlusal) and by 1.0 mm (0.5; 2.0) (VCMX) (p = 0.074) and 1.5 mm (−2.0; 2.0) (SCTG) (p = 0.563) (buccal). Non‐inferiority with a non‐inferiority margin of 1 mm could be demonstrated (p = 0.020); the difference between the two group medians (1.3 mm) for occlusal sites indicated no relevant, but not significant superiority of VCMX versus SCTG (primary endpoint). Pain medication consumption and pain perceived were non‐significantly higher in group SCTG up to day 3. Median physical pain (OHIP‐14) at day 7 was 100% higher for SCTG than for VCMX. The histological analysis revealed well‐integrated grafts. Conclusions: Soft tissue augmentation at implant sites resulted in a similar or higher soft tissue volume increase after 90 days for VCMX versus SCTG. PROM s did not reveal relevant differences between the two groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jcpe.12588

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Thoma, D. S., Zeltner, M., Hilbe, M., Hämmerle, C. H. F., Hüsler, J., & Jung, R. E.
Venue
Journal of Clinical Periodontology
Publisher
Wiley
Published
2016-08-12
Volume
43
Issue
10
Pages
874-885
ISSN
  • 0303-6979 (ISSN-L)
  • 1600-051X
OpenAlex
W2438346556
Cited by
204
References
0
FWCI
10.37
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized controlled clinical study evaluating effectiveness and safety of a volume‐stable collagen matrix compared to autogenous connective tissue grafts for soft tissue augmentation at implant sites. https://app.cochat.ai/papers/10.1111/jcpe.12588
The paper
Thoma, D. S., Zeltner, M., Hilbe, M., Hämmerle, C. H. F., Hüsler, J., & Jung, R. E. (2016). Randomized controlled clinical study evaluating effectiveness and safety of a volume‐stable collagen matrix compared to autogenous connective tissue grafts for soft tissue augmentation at implant sites. Journal of Clinical Periodontology. https://doi.org/10.1111/jcpe.12588

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.