CoChat

Effect of obstructive sleep apnea and its treatment of atrial fibrillation recurrence after radiofrequency catheter ablation: A meta‐analysis

Congrete, Soontharee, Bintvihok, Maythawee, Thongprayoon, Charat, Bathini, Tarun, Boonpheng, Boonphiphop, Sharma, Konika, Chokesuwattanaskul, Ronpichai, Srivali, Narat, Tanawuttiwat, Tanyanan, Cheungpasitporn, Wisit · 2018 · Journal of Evidence-Based Medicine
Cited by 74

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Background/objectives: Patients with obstructive sleep apnea (OSA) have an increased the risk of developing atrial fibrillation (AF). However, it remains unclear if patients with OSA carry a higher risk of recurrent AF after successful catheter ablation. This meta‐analysis was conducted (1) to evaluate the association between OSA and recurrent AF after catheter ablation, and (2) to assess the effect of continuous positive airway pressure (CPAP) on the risk of recurrent AF in patients with OSA. Methods: A comprehensive literature review was conducted using MEDLINE, EMBASE, Cochrane databases from inception through July 2017 to identify studies that evaluated the risk of recurrent AF after successful catheter ablation in patients with OSA were included. Effect estimates from the individual study were extracted and combined using random‐effect, generic inverse variance method of DerSimonian and Laird. Results: Seven observational studies with a total of 4572 patients AF after successful catheter ablation were enrolled. Compared to patients without OSA, the pooled OR of recurrent AF in patients with OSA was 1.70 (95% CI, 1.40‐2.06, I2 = 0). Among OSA patients with AF after successful catheter ablation, the use of CPAP was significantly associated with decreased risk of recurrent AF with pooled OR of 0.28 (0.19‐0.40, I2 = 0). Egger's regression asymmetry test was performed and showed no publication bias for the associations of OSA and CPAP with recurrent AF. Conclusions: Our meta‐analysis suggested a significant association between OSA and recurrent AF after catheter ablation. The use of CPAP in patients with OSA is associated with reduced risk of recurrent AF after catheter ablation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jebm.12313

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Congrete, S., Bintvihok, M., Thongprayoon, C., Bathini, T., Boonpheng, B., Sharma, K., Chokesuwattanaskul, R., Srivali, N., Tanawuttiwat, T., & Cheungpasitporn, W.
Venue
Journal of Evidence-Based Medicine
Publisher
Wiley
Published
2018-08
Volume
11
Issue
3
Pages
145-151
ISSN
  • 1756-5383 (ISSN-L)
  • 1756-5391
OpenAlex
W2885734968
Cited by
74
References
17
FWCI
4.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.