CoChat

Application of the combined FibroMeter vibration‐controlled transient elastography algorithm in Chinese patients with non‐alcoholic fatty liver disease

Loong, Thomson Chi‐Wang, Wei, Jeremy Lok, Leung, Jonathan Chung‐Fai, Wong, Grace Lai‐Hung, Shu, Sally She‐Ting, Chim, Angel Mei‐Ling, Chan, Anthony Wing‐Hung, Choi, Paul Cheung‐Lung, Tse, Yee‐Kit, Chan, Henry Lik‐Yuen, Wong, Vincent Wai‐Sun · 2017 · Journal of Gastroenterology and Hepatology
Cited by 56

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Background and Aim: The FibroMeter vibration‐controlled transient elastography (FM VCTE) is a new formula combining the serum test FM and liver stiffness measurement (LSM) by VCTE. We tested the accuracy and utility of FM VCTE for fibrosis staging in patients with non‐alcoholic fatty liver disease (NAFLD). Methods: Two hundred fifteen NAFLD patients with LSM, FM NAFLD, FM VCTE, and other serum tests (aspartate aminotransferase‐to‐platelet ratio index, fibrosis‐4 index, BARD score, NAFLD fibrosis score, and aspartate aminotransferase‐to‐alanine aminotransferase ratio) performed 1 day before liver biopsy were evaluated. Results: Sixty‐nine (32.1%) and 43 (20.0%) patients had F2‐4 and F3‐4, respectively. LSM had higher diagnostic accuracy (area under receiver‐operating characteristics curves [AUROC] 0.851 for F2‐4, 0.940 for F3‐4; Obuchowski index 0.937 ± 0.007) than all evaluated serum tests, while FM NAFLD was the most accurate serum test (AUROC 0.775 and 0.774; Obuchowski index 0.891 ± 0.013). FM VCTE had similar accuracy to LSM (AUROC 0.855 and 0.901; Obuchowski index 0.927 ± 0.009). LSM had excellent negative predictive values of 92.4% and 99.2% to exclude F2‐4 and F3‐4, but the positive predictive values (PPV) were only 71.4% and 61.0%, respectively. In patients with high LSM, the use of FM VCTE improved the PPV from 71.4% to 84.4% for F2‐4 and from 61.0% to 88.9% for F3‐4. Liver biopsy could be spared in around 50–65% of patients. Conclusions: Liver stiffness measurement alone can confidently exclude significant and advanced fibrosis in NAFLD patients. Using FM VCTE in patients with high liver stiffness can increase the positive predictive value to rule in F2‐4 and F3‐4.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jgh.13671

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 56

Metadata

Authors
Loong, T. C., Wei, J. L., Leung, J. C., Wong, G. L., Shu, S. S., Chim, A. M., Chan, A. W., Choi, P. C., Tse, Y., Chan, H. L., & Wong, V. W.
Venue
Journal of Gastroenterology and Hepatology
Publisher
Wiley
Published
2017-06-22
Volume
32
Issue
7
Pages
1363-1369
ISSN
  • 0815-9319 (ISSN-L)
  • 1440-1746
OpenAlex
W2782807630
Cited by
56
References
9
FWCI
4.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of the combined FibroMeter vibration‐controlled transient elastography algorithm in Chinese patients with non‐alcoholic fatty liver disease. https://app.cochat.ai/papers/10.1111/jgh.13671
The paper
Loong, T. C., Wei, J. L., Leung, J. C., Wong, G. L., Shu, S. S., Chim, A. M., Chan, A. W., Choi, P. C., Tse, Y., Chan, H. L., & Wong, V. W. (2017). Application of the combined FibroMeter vibration‐controlled transient elastography algorithm in Chinese patients with non‐alcoholic fatty liver disease. Journal of Gastroenterology and Hepatology. https://doi.org/10.1111/jgh.13671

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.