Challenges of microtome‐based serial block‐face scanning electron microscopy in neuroscience
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Summary: Serial block‐face scanning electron microscopy (SBEM) is becoming increasingly popular for a wide range of applications in many disciplines from biology to material sciences. This review focuses on applications for circuit reconstruction in neuroscience, which is one of the major driving forces advancing SBEM. Neuronal circuit reconstruction poses exceptional challenges to volume EM in terms of resolution, field of view, acquisition time and sample preparation. Mapping the connections between neurons in the brain is crucial for understanding information flow and information processing in the brain. However, information on the connectivity between hundreds or even thousands of neurons densely packed in neuronal microcircuits is still largely missing. Volume EM techniques such as serial section TEM, automated tape‐collecting ultramicrotome, focused ion‐beam scanning electron microscopy and SBEM (microtome serial block‐face scanning electron microscopy) are the techniques that provide sufficient resolution to resolve ultrastructural details such as synapses and provides sufficient field of view for dense reconstruction of neuronal circuits. While volume EM techniques are advancing, they are generating large data sets on the terabyte scale that require new image processing workflows and analysis tools. In this review, we present the recent advances in SBEM for circuit reconstruction in neuroscience and an overview of existing image processing and analysis pipelines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distinctive Image Features from Scale-Invariant Keypoints
Lowe, D. G. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000029664.99615.94 · Cited by 55,589
The structure of the nervous system of the nematode Caenorhabditis elegans
White, J. G., Southgate, E., Thomson, J. N., & Brenner, S. (1986) · Philosophical Transactions of the Royal Society of London. B, Biological Sciences · doi:10.1098/rstb.1986.0056 · Cited by 5,589 · cited 1×
“The entire nervous system of the nematode Caenorhabditis elegans has been acquired using serial sections and TEM, which led to the first complete connectome of an entire organism (White et al., 1986; Varshney et al., 2011).”
BackgroundProbabilistic diffusion tractography with multiple fibre orientations: What can we gain?
Behrens, T. E. J., Berg, H. J., Jbabdi, S., Rushworth, M. F. S., & Woolrich, M. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.018 · Cited by 3,471
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Serial Block-Face Scanning Electron Microscopy to Reconstruct Three-Dimensional Tissue Nanostructure
Denk, W., & Horstmann, H. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020329 · Cited by 1,644 · cited 4×
“In SBEM [formerly called SBFSEM but renamed by W. Denk (Denk & Horstmann, 2004)], the recording chamber of an SEM is equipped with a microtome.”
BackgroundMethodInfluentialConnectomic reconstruction of the inner plexiform layer in the mouse retina
Helmstaedter, M., Briggman, K. L., Turaga, S. C., Jain, V., Seung, H. S., & Denk, W. (2013) · Nature · doi:10.1038/nature12346 · Cited by 997 · cited 9×
“The SBEM pioneers in the Denk lab recruited hundreds of undergraduates for skeleton tracing of neurons using KNOSSOS (Helmstaedter et al., 2013).”
BackgroundMethodInfluentialWiring specificity in the direction-selectivity circuit of the retina
Briggman, K. L., Helmstaedter, M., & Denk, W. (2011) · Nature · doi:10.1038/nature09818 · Cited by 883 · cited 6×
“This is still a significant challenge as these instruments currently cannot be run for more than 1–2 months (Briggman et al., 2011; Lichtman & Denk, 2011; Helmstaedter et al., 2013) without failure.”
BackgroundMethodInfluentialStructural Properties of the Caenorhabditis elegans Neuronal Network
Varshney, L. R., Chen, B. L., Paniagua, E., Hall, D. H., & Chklovskii, D. B. (2011) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1001066 · Cited by 867 · cited 1×
“The entire nervous system of the nematode Caenorhabditis elegans has been acquired using serial sections and TEM, which led to the first complete connectome of an entire organism (White et al., 1986; Varshney et al., 2011).”
BackgroundEngineered ascorbate peroxidase as a genetically encoded reporter for electron microscopy
Martell, J. D., Deerinck, T. J., Sancak, Y., Poulos, T. L., Mootha, V. K., Sosinsky, G. E., Ellisman, M. H., & Ting, A. Y. (2012) · Nature Biotechnology · doi:10.1038/nbt.2375 · Cited by 722 · cited 1×
“(Martell et al., 2012).”
Serial section scanning electron microscopy of adult brain tissue using focused ion beam milling
Knott, G., Marchman, H., Wall, D., & Lich, B. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3189-07.2008 · Cited by 692
A visual motion detection circuit suggested by Drosophila connectomics
Takemura, S.-Y., Bharioke, A., Lu, Z., Nern, A., Vitaladevuni, S., Rivlin, P. K., Katz, W. T., Olbris, D. J., Plaza, S. M., Winston, P., et al. (2013) · Nature · doi:10.1038/nature12450 · Cited by 686 · cited 5×
“Sections are imaged in a TEM, and imaging approaches such as camera array imaging (TEMCA) with typically 2–4 nm lateral resolution (Bock et al., 2011; Takemura et al., 2013; Atasoy et al., 2014) can acquire images at a rate of 5–8 megapixels s−1 (Bock et al., 2011).”
BackgroundMethodInfluentialSpace–time wiring specificity supports direction selectivity in the retina
EyeWirers, T., Kim, J. S., Greene, M. J., Zlateski, A., Lee, K., Richardson, M., Turaga, S. C., Purcaro, M., Balkam, M., Robinson, A., et al. (2014) · Nature · doi:10.1038/nature13240 · Cited by 450 · cited 2×
“Therefore, new software is under development for computer-assisted, semiautomated large-scale annotation and segmentation (Lowe, 2004; Jain et al., 2007; Chklovskii et al., 2010; Kaynig, Fuchs, et al., 2010; Kim et al., 2014; Maco et al., 2014).”
MethodCATMAID: collaborative annotation toolkit for massive amounts of image data
Saalfeld, S., Cardona, A., Hartenstein, V., & Tomančák, P. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp266 · Cited by 384 · cited 3×
“As the data sets are getting too big for local storage, both, CATMAID and KNOSSOS, feature online streaming of the data from external servers.”
MethodHigh-contrast en bloc staining of neuronal tissue for field emission scanning electron microscopy
Tapia, J. C., Kasthuri, N., Hayworth, K. J., Schalek, R., Lichtman, J. W., Smith, S. J., & Buchanan, J. (2012) · Nature Protocols · doi:10.1038/nprot.2011.439 · Cited by 296 · cited 3×
“However, samples stained by multiple steps of heavy metals show reduced permeability and resin may not be able to fully penetrate (Mikula et al., 2012; Tapia et al., 2012; Starborg et al., 2013).”
BackgroundMethodHayworth, K. J., Morgan, J. L., Schalek, R., Berger, D. R., Hildebrand, D. G. C., & Lichtman, J. W. (2014) · Frontiers in Neural Circuits · doi:10.3389/fncir.2014.00068 · Cited by 282
Cited by
Enhanced FIB-SEM systems for large-volume 3D imaging
Xu, C. S., Hayworth, K. J., Lu, Z., Grob, P., Hassan, A. M., García-Cerdán, J. G., Niyogi, K. K., Nogales, E., Weinberg, R. J., & Hess, H. F. (2017) · eLife · doi:10.7554/elife.25916 · Cited by 411
“, 2006) or diamond knife block-face removal (Denk and Horstmann, 2004; Wanner et al., 2015) lose consistency when attempting z steps between adjacent images below 20 nm.”
BackgroundVolume scanning electron microscopy for imaging biological ultrastructure
Titze, B., & Genoud, C. (2016) · Biology of the Cell · doi:10.1111/boc.201600024 · Cited by 287
Self-citationA Student’s Guide to Neural Circuit Tracing
Saleeba, C., Dempsey, B., Le, S., Goodchild, A., & McMullan, S. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00897 · Cited by 153
Metadata
- Authors
- WANNER, A. A., KIRSCHMANN, M. A., & GENOUD, C.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2015-04-23
- Volume
- 259
- Issue
- 2
- Pages
- 137-142
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W1587124315
- Cited by
- 70
- References
- 15
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.