Extended depth‐of‐field reflected‐light microscopy with a low‐cost robotic microscope and Fiji focus stacking: Workflow integration and baseline evaluation

Ballesteros, Juan M., Garzón, Carlos M.·2026·Journal of Microscopy

Abstract

Optical reflected‐light microscopy is widely used in mechanical and tribological testing laboratories, but its limited depth of field (DOF) restricts imaging of non‐planar post‐test surfaces when high‐NA objectives are needed to resolve fine features. Here we present a low‐cost robotic microscopy system (bill of materials around USD 300) that extends depth of field through controlled axial scanning and computational focus stacking. Built on the OpenFlexure platform and using open‐source software tools, the system captures z ‐stacks and reconstructs all‐in‐focus micrographs in Fiji (ImageJ distribution) using extended‐depth‐of‐field (EDOF) fusion engines. The workflow is demonstrated on mechanically tested surfaces (scratches and indentations), providing all‐in‐focus visualisation of features such as scratch lips, pile‐up, indentation boundaries and microcracks on reflective textured surfaces, with Scanning Electron Microscopy used for cross‐checking of feature detectability. Baseline characterisation includes operational DOF and resolving‐power measurements, a geometric‐distortion assessment using a micrometric grid target, and a time‐cost analysis of stack acquisition. Comparative evaluation of three widely used fusion methods (Sobel, variance and complex wavelets) using image‐quality metrics and visual inspection indicates that complex‐wavelet fusion yields sharper reconstructions and improved edge preservation relative to Sobel and variance, at the expense of higher computation time. Finally, we summarise practical constraints and observed failure modes under representative conditions, providing baseline guidance for routine use, including deployment close to mechanical test stations. LAY DESCRIPTION : Low‐cost reflected‐light microscopy has shallow depth of field when high‐NA objectives image rough surfaces. We demonstrate a fully open (∼USD 300) OpenFlexure‐based robotic microscope with an end‐to‐end Fiji focus‐stacking workflow that produces all‐in‐focus micrographs of scratches and indentations, cross‐checked against SEM. Baseline characterisation covers DOF, resolving power, geometric distortion, and acquisition‐time effects. Complex‐wavelet fusion outperforms Sobel and variance in sharpness at higher computation time. Practical constraints are identified for post‐test failure analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jmi.70161

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

Research works printed but not linked: 27

  1. 10.1364/AO.517997 · DOI
  2. 10.1111/j.1365‐2818.1988.tb04563.x · DOI
  3. 10.1111/j.1365‐2818.2005.01520.x · DOI
  4. 10.1038/s41467‐025‐63691‐w · DOI
  5. 10.1038/s41467‐023‐39860‐0 · DOI
  6. 10.1111/jmi.12433 · DOI
  7. 10.1111/jmi.13219 · DOI
  8. 10.1111/jmi.13064 · DOI
  9. 10.1049/el:20060693 · DOI · Paper page
  10. 10.1002/jemt.20092 · DOI
  11. 10.1186/s12859‐017‐1934‐z · DOI
  12. 10.1002/pro.3993 · DOI
  13. 10.1002/cpz1.849 · DOI
  14. 10.1364/OE.450211 · DOI
  15. 10.1371/journal.pone.0098781 · DOI
  16. 10.1038/s41467‐020‐19447‐9 · DOI
  17. 10.1038/nmeth.2507 · DOI
  18. 10.1002/jemt.24200 · DOI
  19. 10.1038/s41592‐022‐01602‐3 · DOI
  20. 10.1364/BOE.385729 · DOI
  21. 10.1063/1.4941068 · DOI
  22. 10.1590/1980‐5373‐MR‐2019‐0453 · DOI
  23. 10.1093/micmic/ozad051 · DOI
  24. 10.1049/el:20000267 · DOI
  25. 10.1016/j.patrec.2004.03.003 · DOI
  26. 10.1038/s41598‐021‐91654‐w · DOI
  27. 10.1214/20‐AOS2037 · DOI

Metadata

Authors
Ballesteros, J. M., & Garzón, C. M.
Venue
Journal of Microscopy
Publisher
Wiley
Published
2026-08-26
Volume
304
Issue
1
Pages
24-40
ISSN
  • 0022-2720
  • 1365-2818
Cited by
0
Language
en
Funders
Universidad Nacional de Colombia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Extended depth‐of‐field reflected‐light microscopy with a low‐cost robotic microscope and Fiji focus stacking: Workflow integration and baseline evaluation. https://app.cochat.ai/papers/10.1111/jmi.70161
The paper
Ballesteros, J. M., & Garzón, C. M. (2026). Extended depth‐of‐field reflected‐light microscopy with a low‐cost robotic microscope and Fiji focus stacking: Workflow integration and baseline evaluation. Journal of Microscopy. https://doi.org/10.1111/jmi.70161

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.