Concentration‐dependent specimen shrinkage in iodine‐enhanced micro CT
Open accessThe DOI matches its Crossref record.
Abstract
Iodine potassium iodide (I2KI) solution can be employed as a contrast agent for the visualisation of soft tissue structures in micro‐computed tomography studies. This technique provides high resolution images of soft tissue non‐destructively but initial studies suggest that the stain can cause substantial specimen shrinkage. The degree of specimen shrinkage, and potential deformation, is an important consideration when using the data for morphological studies. Here we quantify the macroscopic volume changes in mouse skeletal muscle, cardiac muscle and cerebellum as a result of immersion in the common fixatives 10% phosphate‐buffered formal saline, 70% ethanol and 3% glutaraldehyde, compared with I2KI staining solution at concentrations of 2, 6, 10 and 20%. Immersion in the I2KI solution resulted in dramatic changes of tissue volume, which were far larger than the shrinkage from formalin fixation alone. The degree of macroscopic change was most dependent upon the I2KI concentration, with severe shrinkage of 70% seen in solutions of 20% I2KI after 14 days' incubation. When using this technique care needs to be taken to use the lowest concentration that will give adequate contrast to minimise artefacts due to shrinkage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gignac, P. M., Kley, N. J., Clarke, J. A., Colbert, M. W., Morhardt, A. C., Cerio, D., Cost, I. N., Cox, P. G., Daza, J. D., Early, C. M., et al. (2016) · Journal of Anatomy · doi:10.1111/joa.12449 · Cited by 541
Gignac, P. M., & Kley, N. J. (2014) · Journal of Experimental Zoology Part B: Molecular and Developmental Evolution · doi:10.1002/jez.b.22561 · Cited by 247
X-ray computed tomography in life sciences
Rawson, S. D., Maksimcuka, J., Withers, P. J., & Cartmell, S. H. (2020) · BMC Biology · doi:10.1186/s12915-020-0753-2 · Cited by 164
Musculoskeletal Geometry, Muscle Architecture and Functional Specialisations of the Mouse Hindlimb
Charles, J. P., Cappellari, O., Spence, A. J., Hutchinson, J. R., & Wells, D. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0147669 · Cited by 164
Metadata
- Authors
- Vickerton, P., Jarvis, J., & Jeffery, N.
- Venue
- Journal of Anatomy
- Publisher
- Wiley
- Published
- 2013-05-30
- Volume
- 223
- Issue
- 2
- Pages
- 185-193
- ISSN
- 0021-8782 (ISSN-L)
- 1469-7580
- OpenAlex
- W2172235545
- Cited by
- 189
- References
- 0
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Concentration‐dependent specimen shrinkage in iodine‐enhanced micro CT. https://app.cochat.ai/papers/10.1111/joa.12068
- The paper
- Vickerton, P., Jarvis, J., & Jeffery, N. (2013). Concentration‐dependent specimen shrinkage in iodine‐enhanced micro CT. Journal of Anatomy. https://doi.org/10.1111/joa.12068
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.