Image registration to compensate for EPI distortion in patients with brain tumors: an evaluation of tract-specific effects
Open accessAbstract
BACKGROUND AND PURPOSE: Diffusion magnetic resonance imaging (dMRI) provides preoperative maps of neurosurgical patients’ white matter tracts, but these maps suffer from echo‐planar imaging (EPI) distortions caused by magnetic field inhomogeneities. In clinical neurosurgical planning, these distortions are generally not corrected and thus contribute to the uncertainty of fiber tracking. Multiple image processing pipelines have been proposed for image‐registration‐based EPI distortion correction in healthy subjects. In this article, we perform the first comparison of such pipelines in neurosurgical patient data. METHODS: Five pipelines were tested in a retrospective clinical dMRI dataset of 9 patients with brain tumors. Pipelines differed in the choice of fixed and moving images and the similarity metric for image registration. Distortions were measured in two important tracts for neurosurgery, the arcuate fasciculus and corticospinal tracts. RESULTS: Significant differences in distortion estimates were found across processing pipelines. The most successful pipeline used dMRI baseline and T2‐weighted images as inputs for distortion correction. This pipeline gave the most consistent distortion estimates across image resolutions and brain hemispheres. CONCLUSIONS: Quantitative results of mean tract distortions on the order of 1–2 mm are in line with other recent studies, supporting the potential need for distortion correction in neurosurgical planning. Novel results include significantly higher distortion estimates in the tumor hemisphere and greater effect of image resolution choice on results in the tumor hemisphere. Overall, this study demonstrates possible pitfalls and indicates that care should be taken when implementing EPI distortion correction in clinical settings.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Intermodality registration between dMRI and T1-weighted images can be affected by differences in image resolutions and echo-planar imaging (EPI) distortion in dMRI data.
“For example, the intermodality registration between dMRI and T1-weighted images can be affected by differences in image resolutions (Malinsky et al., 2013) and echo-planar imaging (EPI) distortion in dMRI data (Albi et al., 2018).”
From Quantitative mapping of the brain’s structural connectivity using diffusion MRI tractography: A review (2022) · cites this paper as Albi et al., 2018
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Beyond the arcuate fasciculus: consensus and controversy in the connectional anatomy of language
Dick, A. S., & Tremblay, P. (2012) · Brain · doi:10.1093/brain/aws222 · Cited by 470 · see citing works
Flagged first, then by citations
Research works printed but not linked: 46
- [1]Jellison BJ Field AS Medow J Diffusion tensor imaging of cerebral white matter: a pictorial review of physics, fiber tract anatomy, and tumor imaging patterns Am J Neuroradiol 2005 25 356 69 PMC8158568 15037456
- [2]Wu JS Zhou LF Tang WJ Clinical evaluation and follow-up outcome of diffusion tensor imaging-based functional neuronavigation: a prospective, controlled study in patients with gliomas involving pyramidal tracts Neurosurgery 2007 61 935 49 18091270
- [3]Jezzard P Clare S Sources of distortion in functional MRI data Hum Brain Mapp 1999 8 80 5 10524596 PMC6873315
- [4]Jezzard P Balaban RS Correction for geometric distortion in echo planar images from B0 field variations Magn Reson Med 1995 34 65 73 7674900
- [5]Merhof D Soza G Stadlbauer A Correction of susceptibility artifacts in diffusion tensor data using non-linear registration Med Image Anal 2007 11 588 603 17664081
- [8]Irfanoglu MO Walker L Sarlls J Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography results Neuroimage 2012 61 275 88 22401760 PMC3653420
- [9]Bagley LJ Grossman RI Judy KD Gliomas: correlation of magnetic susceptibility artifact with histologic grade Radiology 1997 202 511 6 9015082
- [10]Krings T Reinges M Erberich S Functional MRI for presurgical planning: problems, artefacts, and solution strategies J Neurol Neurosurg Psychiatry 2001 70 749 60 11385009 PMC1737418
- [11]Kim MJ Holodny AI Hou BL The effect of prior surgery on blood oxygen level–dependent functional MR imaging in the preoperative assessment of brain tumors Am J Neuroradiol 2005 26 1980 5 16155146 PMC8148840
- [12]Wu M Chang LC Walker L Comparison of EPI distortion correction methods in diffusion tensor MRI using a novel framework MICCAI 2008 321 9 18982621 PMC4819327
- [13]Avants BB Epstein CL Grossman M Symmetric diffeomorphic image registration with cross-correlation: evaluating automated labeling of elderly and neurodegenerative brain Med Image Anal 2008 12 26 41 17659998 PMC2276735
- [14]Gholipour A Kehtarnavaz N Scherrer B On the accuracy of unwarping techniques for the correction of susceptibility-induced geometric distortion in magnetic resonance echo-planar images IEEE 2011 6997 7000 PMC3675776 22255949
- [15]Tao R Fletcher PT Gerber S A variational image-based approach to the correction of susceptibility artifacts in the alignment of diffusion weighted and structural MRI Inf Process Med Imaging 2009 664 75 19694302 PMC4031680
- [16]Bhushan C Haldar JP Choi S Co-registration and distortion correction of diffusion and anatomical images based on inverse contrast normalization Neuroimage 2015 115 269 80 25827811 PMC4461504
- [17]Tao G He R Poonawalla AH The correction of EPI-induced geometric distortions and their evaluation IEEE 2007 6 225
- [18]Kybic J Thévenaz P Nirkko A Unwarping of unidirectionally distorted EPI images IEEE Trans Med Imaging 2000 19 80 93 10784280
- [19]Ardekani S Sinha U Geometric distortion correction of high-resolution 3 T diffusion tensor brain images Magn Reson Med 2005 54 1163 71 16187289
- [20]Malinsky M Peter R Hodneland E Registration of FA and T1-weighted MRI data of healthy human brain based on template matching and normalized cross-correlation J Digit Imaging 2013 26 774 85 23288436 PMC3705011
- [22]Catani M Mesulam M The arcuate fasciculus and the disconnection theme in language and aphasia: history and current state Cortex 2008 44 953 61 18614162 PMC2740371
- [24]Oguz I Farzinfar M Matsui J DTIPrep: quality control of diffusion-weighted images Front Neuroinform 2014 8 PMC3906573 24523693
- [25]Smith SM Fast robust automated brain extraction Hum Brain Mapp 2002 17 143 55 12391568 PMC6871816
- [26]Klein A Andersson J Ardekani BA Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration Neuroimage 2009 46 786 802 19195496 PMC2747506
- [27]Risholm P Golby AJ Wells W Multimodal image registration for preoperative planning and image-guided neurosurgical procedures Neurosurg Clin NAm 2011 22 197 206 PMC3080117 21435571
- [28]Pluim PJ Maintz JA Viergever MA Mutual-information-based registration of medical images: a survey IEEE Trans Med Imaging 2003 22 986 1004 12906253
- [29]Klein S Staring M Murphy K Elastix: a toolbox for intensity-based medical image registration IEEE Trans Med Imaging 2010 29 196 205 19923044
- [30]Malcolm JG Shenton ME Rathi Y Filtered multitensor tractography IEEE Trans Med Imaging 2010 29 1664 75 20805043 PMC3045040
- [31]Chen Z Tie Y Olubiyi O Reconstruction of the arcuate fasciculus for surgical planning in the setting of peritumoral edema using two-tensor unscented Kalman filter tractography Neuroimage Clin 2015 7 815 22 26082890 PMC4459040
- [32]Cusack R Brett M Osswald K An evaluation of the use of magnetic field maps to undistort echo-planar images Neuroimage 2003 189 127 42 12507450
- [33]Hutton A Bork A Josephs O Image distortion correction in fMRI: a quantitative evaluation Neuroimage 2002 16 217 40 11969330
- [34]Irfanoglu MO Modi P Nayak A DR-BUDDI (diffeomorphic registration for blip-up blip-down diffusion imaging) method for correcting echo planar imaging distortions Neuroimage 2015 106 284 99 25433212 PMC4286283
- [35]Daducci A Gerhard S Griffa A The connectome mapper: an open-source processing pipeline to map connectomes with MRI PLoS One 2012 7 e48121 23272041 PMC3525592
- [37]Pujol S Wells W Pierpaoli C The DTI challenge: toward standardized evaluation of diffusion tensor imaging tractography for neurosurgery J Neuroimaging 2015 25 875 82 26259925 PMC4641305
- [38]Treiber JM White NS Steed TC Characterization and correction of geometric distortions in 814 diffusion weighted images PLoS One 2016 11 e0152492 27027775 PMC4814112
- [39]Kaus MR Warfield SK Nabavi A Automated segmentation of MR images of brain tumors Radiology 2001 218 586 91 11161183
- [40]Brett M Leff AP Rorden C Spatial normalization of brain images with focal lesions using cost function masking Neuroimage 2001 14 486 500 11467921
- [41]Clatz O Delingette H Talos IF Robust nonrigid registration to capture brain shift from intraoperative MRI IEEE Trans Med Imaging 2005 24 1417 27 16279079 PMC2042023
- [42]Andersson JL Hutton C Ashburner J Modeling geometric deformations in EPI time series Neuroimage 2001 13 903 19 11304086
- [43]Chang H Fitzpatrick JM A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities IEEE Trans Med Imaging 1992 11 319 29 18222873
- [44]Embleton KV Haroon HA Morris DM Distortion correction for diffusion-weighted MRI tractography and fMRI in the temporal lobes Hum Brain Mapp 2010 31 1570 87 20143387 PMC6870737
- [45]Holland D Kuperman JM Dale AM Efficient correction of inhomogeneous static magnetic field-induced distortion in echo planar imaging Neuroimage 2010 50 175 83 19944768 PMC2819607
- [46]Gelman N Silavi A Anazodo U A hybrid strategy for correcting geometric distortion in echo-planar images Magn Reson Imaging 2014 32 590 3 24650682
- [47]Hong X To XV Teh I Evaluation of EPI distortion correction methods for quantitative MRI of the brain at high magnetic field Magn Reson Imaging 2015 33 1098 105 26117700
- [48]Avants BB Tustison NJ Song G A reproducible evaluation of ANTs similarity metric performance in brain image registration Neuroimage 2011 54 2033 44 20851191 PMC3065962
- [49]Andersson JL Sotiropoulos SN An integrated approach to correction for offresonance effects and subject movement in diffusion MR imaging Neuroimage 2016 125 1063 78 26481672 PMC4692656
- [51]Wells WM Viola P Atsumi H Multimodal volume registration by maximization of mutual information Med Image Anal 1996 1 35 51 9873920
- [52]Maes F Collignon A Vandermeulen D Multimodality image registration by maximization of mutual information IEEE Trans Med Imaging 1997 16 187 98 9101328
Cited by
Sorted by citations
Zhang, F., Daducci, A., He, Y., Schiavi, S., Seguin, C., Smith, R. E., Yeh, C.-H., Zhao, T., & O’Donnell, L. J. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2021.118870 · Cited by 302 · see citing works
“echo-planar imaging (EPI) distortion in dMRI data [4].”
BackgroundSelf-citationAydogan, D. B., Jacobs, R., Dulawa, S., Thompson, S. L., Francois, M. C., Toga, A. W., Dong, H., Knowles, J. A., & Shi, Y. (2018) · Brain Structure and Function · doi:10.1007/s00429-018-1663-8 · Cited by 72 · see citing works
- Authors
- Albi, A., Meola, A., Zhang, F., Kahali, P., Rigolo, L., Tax, C. M. W., Ciris, P. A., Essayed, W. I., Unadkat, P., Norton, I., Rathi, Y., Olubiyi, O., Golby, A. J., & O'Donnell, L. J.
- Affiliations
- Brigham and Women's Hospital (US)
- Brigham and Women's Hospital Harvard Medical School Boston MA
- ORCID
- Venue
- Journal of Neuroimaging
- Publisher
- Wiley
- Published
- 2018-01-10
- Volume
- 28
- Issue
- 2
- Pages
- 173-182
- ISSN
- 1051-2284 (ISSN-L)
- 1552-6569
- PMC
- PMC5844838
- OpenAlex
- W2783918318
- Cited by
- 19
- References
- 1
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 2 · 2019: 4 · 2018: 1
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Journal of Neuroimaging (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- ORCA Online Research @Cardiff (Cardiff University) (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Funders
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (612.001.104)
- National Institutes of Health (P41 EB015898, P41 EB015902, R01 MH074794, R01 MH097979, R03 NS088301, R21 CA198740, R25 CA089017, U01 CA199459, U01 NS083223)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Keywords
- diffusion MRI, brain tumors, image registration, white matter tracts, arcuate fasciculus, corticospinal tract, neurosurgical planning, T2-weighted imaging, image resolution, tractography
- MeSH terms
- Adult, Aged, Algorithms, Brain, Brain Neoplasms, Female, Humans, Image Processing, Computer-Assisted, Male, Middle Aged, Retrospective Studies, Artifacts, Echo-Planar Imaging, Neurosurgical Procedures, Diffusion Magnetic Resonance Imaging, White Matter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review