Cited by 16Dental Implant Techniques and OutcomesBone Tissue Engineering MaterialsPolymer Surface Interaction Studies

Polydopamine deposition with anodic oxidation for better connective tissue attachment to transmucosal implants

Teng, F., Chen, H., Xu, Y., Liu, Y., Ou, G.·2018·Journal of Periodontal Research

Abstract

Background and objective Nowadays, most designs for the transmucosal surface of implants are machined-smooth. However, connective tissue adhered to the smooth surface of an implant has poor mechanical resistance, which can render separation of tissue from the implant interface and induce epithelial downgrowth. Modification of the transmucosal surface of implants, which can help form a good seal of connective tissue, is therefore desired. We hypothesized that anodic oxidation (AO) and polydopamine (PD) deposition could be used to enhance the attachment between an implant and peri-implant connective tissue. We tested this hypothesis in the mandibles of Beagle dogs. Material and methods AO and PD were used to modify the transmucosal region of transmucosal implants (implant neck). The surface microstructure, surface roughness and elemental composition were investigated in vitro. L929 mouse fibroblasts were cultured to test the effect of PD on cell adhesion. Six Beagle dogs were used for the in vivo experiment (n = 6 dogs per group). Three months after building the edentulous animal model, four groups of implants (control, AO, PD and AO + PD) were inserted. After 4 months of healing, samples were harvested for histometric analyses. Results The surfaces of anodized implant necks were overlaid with densely distributed pores, 2-7 μm in size. On the PD-modified surfaces, N1s, the chemical bond of nitrogen in PD, was detected using X-ray photoelectron spectroscopy. L929 developed pseud…

Integrity signals

Registry

Crossref · 10.1111/jre.12509

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • For implant and bone tissue engineering applications, the evidence is relatively stronger because both in vitro cell studies and in vivo animal implantation or bone defect models have been reported.

    “For implant and bone tissue engineering applications, the evidence is relatively stronger because both in vitro cell studies and in vivo animal implantation or bone defect models have been reported.39”

Cited by

Sorted by citations

Authors
Teng, F., Chen, H., Xu, Y., Liu, Y., & Ou, G.
Affiliations
  • Sichuan University (CN)
  • Chengdu Medical College (CN)
  • Academic Center for Dentistry Amsterdam (NL)
Corresponding author
Ou, G.
Venue
Journal of Periodontal Research
Publisher
Wiley
Published
2017-10-24
Volume
53
Issue
2
Pages
222-231
ISSN
  • 0022-3484 (ISSN-L)
  • 1600-0765
OpenAlex
W2766922146
Cited by
16
References
0
Citations by year
2025: 1 · 2024: 3 · 2023: 2 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 2
FWCI
1.79
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Periodontal Research (publishedVersion)
  • PubMed (publishedVersion)
  • UvA-DARE (University of Amsterdam) (submittedVersion)
  • VU Research Portal (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Funders
National Natural Science Foundation of China (81070868/H1409)
Topics
  • Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
Keywords
polydopamine coating, anodic oxidation, epithelial downgrowth, fibroblast adhesion, surface roughness, osseointegrated implants, edentulous mandible
MeSH terms
Animals, Cell Adhesion, Connective Tissue, Dental Implantation, Endosseous, Dogs, Epithelial Attachment, Fibroblasts, Indoles, Mandible, Oxidation-Reduction, Polymers, Surface Properties, Time Factors, Titanium, Dental Implants, Osseointegration, Dental Prosthesis Design, Coated Materials, Biocompatible, Models, Animal, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review