Standardization of microparticle enumeration across different flow cytometry platforms: results of a multicenter collaborative workshop
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Essentials The clinical enumeration of microparticles (MPs) is hampered by a lack of standardization. A new strategy to standardize MP counts by flow cytometry was evaluated in a multicenter study. No difference was found between instruments using forward or side scatter as the trigger parameter. This study demonstrated that beads can be used as a standardization tool for MPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huber, P. J. (1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250 · Cited by 7,066
Cited by
Théry, C., Witwer, K. W., Aikawa, E., Alcaraz, M. J., Anderson, J. D., Andriantsitohaina, R., Antoniou, A., Arab, T., Archer, F., Atkin‐Smith, G. K., et al. (2018) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2018.1535750 · Cited by 11,099
“…number can be measured by light scattering technologies, such as nanoparticle tracking analysis (NTA); by standard flow cytometry for larger EVs [164 – 167] or high resolution flow cytometry for smaller EVs [127,168 – 176]; by resistive pulse sensing (RPS) for a wide range of sizes, depending…”
Self-citationMethodological Guidelines to Study Extracellular Vesicles
Coumans, F. A. W., Brisson, A. R., Buzas, E. I., Dignat-George, F., Drees, E. E. E., El-Andaloussi, S., Emanueli, C., Gasecka, A., Hendrix, A., Hill, A. F., et al. (2017) · Circulation Research · doi:10.1161/circresaha.117.309417 · Cited by 1,017
Self-citationIsolation, cultivation, and characterization of human mesenchymal stem cells
Mushahary, D., Spittler, A., Kasper, C., Weber, V., & Charwat, V. (2018) · Cytometry Part A · doi:10.1002/cyto.a.23242 · Cited by 599
Gupta, D., Zickler, A. M., & El Andaloussi, S. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113961 · Cited by 418
Extracellular Vesicle Quantification and Characterization: Common Methods and Emerging Approaches
Hartjes, T. A., Mytnyk, S., Jenster, G. W., van Steijn, V., & van Royen, M. E. (2019) · Bioengineering · doi:10.3390/bioengineering6010007 · Cited by 342
Metadata
- Authors
- Cointe, S., Judicone, C., Robert, S., Mooberry, M. J., Poncelet, P., Wauben, M., Nieuwland, R., Key, N. S., Dignat‐George, F., & Lacroix, R.
- Venue
- Journal of Thrombosis and Haemostasis
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 15
- Issue
- 1
- Pages
- 187-193
- ISSN
- 1538-7836 (ISSN-L)
- OpenAlex
- W2521450141
- Cited by
- 129
- References
- 1
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Standardization of microparticle enumeration across different flow cytometry platforms: results of a multicenter collaborative workshop. https://app.cochat.ai/papers/10.1111/jth.13514
- The paper
- Cointe, S., Judicone, C., Robert, S., Mooberry, M. J., Poncelet, P., Wauben, M., Nieuwland, R., Key, N. S., Dignat‐George, F., & Lacroix, R. (2017). Standardization of microparticle enumeration across different flow cytometry platforms: results of a multicenter collaborative workshop. Journal of Thrombosis and Haemostasis. https://doi.org/10.1111/jth.13514
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.