The DOI matches its Crossref record; the references it cites are not checked yet.
Guidance on the critical shortage of sodium citrate coagulation tubes for hemostasis testing
Open accessAbstract
Recent manufacturing problems and increased utilization has created a shortage of 3.2% sodium citrate blood collection tubes used for coagulation testing, causing stakeholders such as hospitals, clinics and laboratories, to find suitable alternatives. Considerations for in-house citrate blood collection tube preparations or purchasing commercial products from unknown manufacturing sources is of particular concern to laboratories that perform coagulation testing. It is well recognized that variability exists between citrate blood collection tube manufacturers, thereby making any transition to new blood collection methods more challenging than simply switching to a new source. This document provides provisional guidance for validating alternative sources of sodium citrate blood collection tubes (commercial or in-house preparations) prior to clinical implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
References 15 · Cited by 25
Research works printed but not linked: 1
- CLSI. Collection, transport, and processing of blood specimens for testing plasma‐based coagulation assays and molecular hemostasis assays; Approved Guideline ‐ Fifth Edition. CLSI document H21‐A5. 2008. Clinical and Laboratory Standards Institute. Wayne, PA.
Metadata
- Authors
- Gosselin, R. C., Bowyer, A., Favaloro, E. J., Johnsen, J. M., Lippi, G., Marlar, R. A., Neeves, K., & Rollins‐Raval, M. A.
- Affiliations
- UC Davis Health (US)
- Royal Hallamshire Hospital (GB)
- Westmead Hospital (AU)
- University of Washington (US)
- University of Verona (IT)
- University of New Mexico (US)
- University of Colorado Anschutz (US)
- Corresponding author
- Gosselin, Robert C.
- ORCID
- Venue
- Journal of Thrombosis and Haemostasis
- Publisher
- Elsevier BV
- Published
- 2021-11
- Volume
- 19
- Issue
- 11
- Pages
- 2857-2861
- ISSN
- 1538-7836 (ISSN-L)
- PMC
- PMC9290683
- OpenAlex
- W3197467153
- Cited by
- 25
- References
- 15
- Citations by year
- 2026: 5 · 2025: 2 · 2024: 7 · 2023: 6 · 2022: 3 · 2021: 1
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Thrombosis and Haemostasis (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- UNM’s Digital Repository (University of New Mexico) (submittedVersion)
- Charles Sturt University Research Output (CRO) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Keywords
- coagulation tests, hemostasis testing, supply shortages
- MeSH terms
- Sodium Citrate, Anticoagulants, Blood Coagulation, Blood Coagulation Tests, Blood Specimen Collection, Hemostasis, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review