Abstract

Background & Aims: Despite the important clinical value of hepatic venous pressure gradient (HVPG) and its increasing use, no specific balloon occlusion catheters have been designed to cannulate liver veins. The aim of the study was to evaluate the clinical applicability of a novel balloon (NC) occlusion catheter specifically designed for HVPG measurement. Methods: Comparison of a new CE‐certified 7 French balloon occlusion catheter with a 150° angled tip and radiopaque markers (NC, Pejcl Medizintechnik, Austria), to a commonly used straight balloon catheter (SC; Boston Scientific, USA). Successful liver vein cannulation rate, need for extra equipment and total fluoroscopy time were recorded. Experts (>200) and novices (<20) in HVPG measurements were evaluated separately. Results: 566 HVPG measurements taken by 11 investigators (five experts and six novices) were analysed. Overall, HVPG could be successfully measured in 98.7% of cases. The rate of successful liver vein cannulation at first attempt was significantly higher among experts when compared to novices (87.3% vs 67.3%, P < 0.001). Moreover, the rate of successful liver vein cannulation without need for any additional equipment was higher when using the NC, both among experts (NC:91.9% vs SC:80.6%, P = 0.03) and novices (NC:73.3% vs SC:50.7%, P = 0.001). The mean fluoroscopy time needed to cannulate the hepatic vein was significantly shorter in experts as compared to novices [2.37(0.10–26) vs 5.2(0.6–30.2] min, P < 0.0001), but not significantly different between catheters. Conclusions: Both novices and experts achieve higher liver vein cannulation rates using the new specifically designed catheter. The use of the novel catheter might increase rates of successful liver vein cannulation and reduce the need for additional equipment, especially in novices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/liv.12783

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 62

Metadata

Authors
Ferlitsch, A., Bota, S., Paternostro, R., Reiberger, T., Mandorfer, M., Heinisch, B., Salzl, P., Schwarzer, R., Sieghart, W., Peck‐Radosavljevic, M., & Ferlitsch, M.
Venue
Liver International
Publisher
Wiley
Published
2015-01-30
Volume
35
Issue
9
Pages
2115-2120
ISSN
  • 0106-9543 (ISSN-L)
  • 1478-3223
  • 1478-3231
OpenAlex
W2076891917
Cited by
62
References
0
FWCI
2.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a new balloon occlusion catheter specifically designed for measurement of hepatic venous pressure gradient. https://app.cochat.ai/papers/10.1111/liv.12783
The paper
Ferlitsch, A., Bota, S., Paternostro, R., Reiberger, T., Mandorfer, M., Heinisch, B., Salzl, P., Schwarzer, R., Sieghart, W., Peck‐Radosavljevic, M., & Ferlitsch, M. (2015). Evaluation of a new balloon occlusion catheter specifically designed for measurement of hepatic venous pressure gradient. Liver International. https://doi.org/10.1111/liv.12783

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.