Impact of skin capsular distance on the performance of controlled attenuation parameter in patients with chronic liver disease
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background & Aims: Controlled attenuation parameter (CAP) is a non‐invasive method for evaluating hepatic steatosis. However, larger skin capsular distance (SCD) can affect the accuracy. The aim of this study was to investigate the impact of SCD on the diagnostic performance of CAP and liver stiffness measurement (LSM). Methods: Of 101 patients with non‐alcoholic fatty liver disease (NAFLD) and 280 patients with chronic hepatitis B (CHB) who underwent liver biopsy were prospectively recruited. CAP, LSM and SCD were performed using FibroScan with M probe. The areas under receiver operating characteristics curves (AUROC s) were calculated to determine the diagnostic efficacy. The optimal thresholds were defined by the maximum Youden index. Results: SCD (B 30.34, P < 0.001) and hepatic steatosis (B 23.04, P < 0.001) were independently associated with CAP by multivariate analysis. The AUROC s were slightly higher for SCD <25 mm compared to those for SCD ≥25 mm for steatosis ≥5% (0.88 vs. 0.81), >33% (0.90 vs. 0.85) and >66% (0.84 vs. 0.72). For SCD <25 mm, the optimal CAP cut‐offs for differentiating steatosis ≥5%, >33% and >66% were 255.0 dB/m, 283.5 dB/m and 293.5 dB/m. However, cut‐offs were elevated by approximately 60–70 dB/m for SCD ≥25 mm. When stratified by fibrosis grade, LSM was significantly affected by SCD ≥25 mm for advanced fibrosis (≥F3) in NAFLD, but not in CHB. Conclusion: CAP is a promising tool for detecting and quantifying hepatic steatosis. SCD ≥25 mm may cause overestimation of steatosis. Similarly, SCD ≥25 mm affects the detection of advanced fibrosis by LSM in NAFLD patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wong, V. W.-S., Vergniol, J., Wong, G. L.-H., Foucher, J., Chan, H. L.-Y., Le Bail, B., Choi, P. C.-L., Kowo, M., Chan, A. W.-H., Merrouche, W., et al. (2010) · Hepatology · doi:10.1002/hep.23312 · Cited by 1,322
Extrahepatic cholestasis increases liver stiffness (FibroScan) irrespective of fibrosis
Millonig, G., Reimann, F. M., Friedrich, S., Fonouni, H., Mehrabi, A., Büchler, M. W., Seitz, H. K., & Mueller, S. (2008) · Hepatology · doi:10.1002/hep.22577 · Cited by 599
Liver Stiffness Measurement Using XL Probe in Patients With Nonalcoholic Fatty Liver Disease
Wong, V. W.-S., Vergniol, J., Wong, G. L.-H., Foucher, J., Chan, A. W.-H., Chermak, F., Choi, P. C.-L., Merrouche, W., Chu, S. H.-T., Pesque, S., et al. (2012) · American Journal of Gastroenterology · doi:10.1038/ajg.2012.331 · Cited by 345 · cited 1×
“Although an XL probe has been designed for overweight and obese patients, it is not widely available (11).”
Background
Cited by
Karlas, T., Petroff, D., Sasso, M., Fan, J.-G., Mi, Y.-Q., de Lédinghen, V., Kumar, M., Lupsor-Platon, M., Han, K.-H., Cardoso, A. C., et al. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2016.12.022 · Cited by 1,275
“[53] Shen F, Zheng R, Shi J, Mi Y, Chen G, Hu X et al.”
BackgroundSelf-citationMózes, F. E., Lee, J. A., Selvaraj, E. A., Jayaswal, A. N. A., Trauner, M., Boursier, J., Fournier, C., Staufer, K., Stauber, R. E., Bugianesi, E., et al. (2022) · Gut · doi:10.1136/gutjnl-2021-324243 · Cited by 556
Self-citationUltrasound-based techniques for the diagnosis of liver steatosis
Ferraioli, G., & Monteiro, L. B. S. (2019) · World Journal of Gastroenterology · doi:10.3748/wjg.v25.i40.6053 · Cited by 506
Selvaraj, E. A., Mózes, F. E., Jayaswal, A. N. A., Zafarmand, M. H., Vali, Y., Lee, J. A., Levick, C. K., Young, L. A. J., Palaniyappan, N., Liu, C.-H., et al. (2021) · Journal of Hepatology · doi:10.1016/j.jhep.2021.04.044 · Cited by 376
“…P, CS Biopsyproven NAFLD 324 54±13 44 - 46 1 1 (>300 examinations) Rosso 2016 (Italy)[69] SC, P, CS Chronic liver disease: Suspected NAFLD 105 45±12 72 28±4 - 1 - Seki 2017 (Japan)[70] SC, P, CS Biopsyproven NAFLD 171 57±14 50 28±5 - 1 - Shen 2015 (China)[71] MC, P, CS Biopsyproven…”
MethodPetroff, D., Blank, V., Newsome, P. N., Shalimar, Voican, C. S., Thiele, M., de Lédinghen, V., Baumeler, S., Chan, W. K., Perlemuter, G., et al. (2021) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(20)30357-5 · Cited by 268
“…probe, extreme cases with BMI < 18 kg/m² were not considered, and M probe was not accepted in cases with BMI > 35 kg/m² unless the probe was selected by the internal software algorithm or SLD was 25 mm. 34 In all analyses of diagnostic performance, the data from the correct probe were always used.”
Method
Metadata
- Authors
- Shen, F., Zheng, R., Shi, J., Mi, Y., Chen, G., Hu, X., Liu, Y., Wang, X., Pan, Q., Chen, G., Chen, J., Xu, L., Zhang, R., Xu, L., & Fan, J.
- Venue
- Liver International
- Publisher
- Wiley
- Published
- 2015-03-06
- Volume
- 35
- Issue
- 11
- Pages
- 2392-2400
- ISSN
- 0106-9543 (ISSN-L)
- 1478-3223
- 1478-3231
- OpenAlex
- W1997679693
- Cited by
- 88
- References
- 3
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of skin capsular distance on the performance of controlled attenuation parameter in patients with chronic liver disease. https://app.cochat.ai/papers/10.1111/liv.12809
- The paper
- Shen, F., Zheng, R., Shi, J., Mi, Y., Chen, G., Hu, X., Liu, Y., Wang, X., Pan, Q., Chen, G., Chen, J., Xu, L., Zhang, R., Xu, L., & Fan, J. (2015). Impact of skin capsular distance on the performance of controlled attenuation parameter in patients with chronic liver disease. Liver International. https://doi.org/10.1111/liv.12809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.