Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 237

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Clinical value of liver ultrasound for the diagnosis of nonalcoholic fatty liver disease in overweight and obese patients

Bril, Fernando, Ortiz‐Lopez, Carolina, Lomonaco, Romina, Orsak, Beverly, Freckleton, Michael, Chintapalli, Kedar, Hardies, Jean, Lai, Song, Solano, Felipe, Tio, Fermin, Cusi, Kenneth · 2015 · Liver International

Abstract

Background & Aims: Liver ultrasound (US) is usually used in the clinical setting for the diagnosis and follow‐up of patients with nonalcoholic fatty liver disease (NAFLD). However, no large study has carefully assessed its performance using a semiquantitative ultrasonographic scoring system in overweight/obese patients, in comparison to magnetic resonance spectroscopy (1 H‐MRS) and histology. Methods: We recruited 146 patients and performed: a liver US using a 5‐parameter scoring system, a liver 1 H‐MRS to quantify liver fat content, and a liver biopsy to assess histology. All measurements were repeated in a subgroup of patients (n = 62) after 18 months of follow‐up. Results: The performance of liver US (parenchymal echo alone) was rather modest, and significantly worse than 1 H‐MRS (AUROC: 0.82 [0.69–0.94] vs. 0.96 [0.90–1.00]; P = 0.04). However, the AUROC improved when different echographic parameters were taken into account (AUROC: 0.89 [0.83–0.96], P = 0.15 against 1 H‐MRS). Optimum sensitivity for liver US was achieved at a liver fat content ≥12.5%, suggesting that below this threshold, liver US is less sensitive. Liver 1 H‐MRS showed a high accuracy for the diagnosis of NAFLD, and correlated strongly with histological steatosis (r = 0.73, P < 0.0001). None of the imaging tests was adequate enough to predict changes over time in histology. Conclusions: Despite its widespread use, liver US has several important limitations that healthcare providers should recognize, particularly because of its low sensitivity. Using a combination of echographic parameters, liver US showed a significant improvement in its diagnostic performance, but still was of limited value for monitoring treatment over time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/liv.12840

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 237

Metadata

Authors
Bril, F., Ortiz‐Lopez, C., Lomonaco, R., Orsak, B., Freckleton, M., Chintapalli, K., Hardies, J., Lai, S., Solano, F., Tio, F., & Cusi, K.
Venue
Liver International
Publisher
Wiley
Published
2015-04-27
Volume
35
Issue
9
Pages
2139-2146
ISSN
  • 0106-9543 (ISSN-L)
  • 1478-3223
  • 1478-3231
OpenAlex
W2126285374
Cited by
237
References
2
FWCI
10.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.