Therapy-Related Explants After Spinal Cord Stimulation: Results of an International Retrospective Chart Review Study
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVES: Clinical trials of spinal cord stimulation (SCS) have largely focused on conversion from trial to permanent SCS and the first years after implant. This study evaluates the association of type of SCS and patient characteristics with longer-term therapy-related explants. MATERIALS AND METHODS: Implanting centers in three European countries conducted a retrospective chart review of SCS systems implanted from 2010 to 2013. Ethics approval or waiver was obtained, and informed consent was not required. The chart review recorded implants, follow-up visits, and date and reasons for any explants through mid-2016. Results are presented using Cox regression to determine factors associated with explant for inadequate pain relief. RESULTS: Four implanting centers in three countries evaluated 955 implants, with 8720 visits over 2259 years of follow-up. Median age was 53 years; 558 (58%) were female. Explant rate was 7.9% per year. Over half (94 of 180) of explants were for inadequate pain relief, including 32/462 (6.9%) of implants with conventional nonrechargeable SCS, 37/329 (11.2%) with conventional rechargeable and 22/155 (14.2%) with high-frequency (10 kHz) rechargeable SCS. A higher explant rate was found in univariate regression for conventional rechargeable (HR 1.98, p = 0.005) and high-frequency stimulation (HR 1.79, p = 0.035) than nonrechargeable SCS. After covariate adjustment, the elevated explant rate persisted for conventional rechargeable SCS (HR 1.95, p = 0.011), but was not significant for high-frequency stimulation (HR 1.71, p = 0.069). CONCLUSIONS: This international, real-world study found higher explant rates for conventional rechargeable and high-frequency SCS than nonrechargeable systems. The increased rate for conventional rechargeable stimulation persisted after covariate adjustment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mekhail, N., Levy, R. M., Deer, T. R., Kapural, L., Li, S., Amirdelfan, K., Hunter, C. W., Rosen, S. M., Costandi, S. J., Falowski, S. M., et al. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30414-4 · Cited by 357
Unique Characteristics of the Dorsal Root Ganglion as a Target for Neuromodulation
Esposito, M. F., Malayil, R., Hanes, M., & Deer, T. (2019) · Pain Medicine · doi:10.1093/pm/pnz012 · Cited by 232
“distribution into the painful area [65–67] or compensatory spinal plasticity/habituation resulting in loss of therapeutic effect [68,69].”
BackgroundRusso, M., Brooker, C., Cousins, M. J., Taylor, N., Boesel, T., Sullivan, R., Holford, L., Hanson, E., Gmel, G. E., Shariati, N. H., et al. (2020) · Neurosurgery · doi:10.1093/neuros/nyaa003 · Cited by 95
(2013) · PubMed · Cited by 37
Metadata
- Authors
- Van Buyten, J.-P., Wille, F., Smet, I., Wensing, C., Breel, J., Karst, E., Devos, M., Pöggel-Krämer, K., & Vesper, J.
- Venue
- Neuromodulation: Technology at the Neural Interface
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 20
- Issue
- 7
- Pages
- 642-649
- ISSN
- 1094-7159 (ISSN-L)
- OpenAlex
- W2748476908
- Cited by
- 150
- References
- 0
- FWCI
- 17.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.