The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Isotope‐ratio infrared spectroscopy: a reliable tool for the investigation of plant‐water sources?
Open accessAbstract
Summary: Stable isotopes are extensively used as tracers for the study of plant‐water sources. Isotope‐ratio infrared spectroscopy (IRIS) offers a cheaper alternative to isotope‐ratio mass spectroscopy (IRMS), but its use in studying plant and soil water is limited by the spectral interference caused by organic contaminants. Here, we examine two approaches to cope with contaminated samples in IRIS: on‐line oxidation of organic compounds (MCM) and post‐processing correction. We assessed these methods compared to IRMS across 136 samples of xylem and soil water, and a set of ethanol– and methanol–water mixtures. A post‐processing correction significantly improved IRIS accuracy in both natural samples and alcohol dilutions, being effective with concentrations up to 8% of ethanol and 0.4% of methanol. MCM outperformed the post‐processing correction in removing methanol interference, but did not effectively remove interference for high concentrations of ethanol. By using both approaches, IRIS can overcome with reasonable accuracy the analytical uncertainties associated with most organic contaminants found in soil and xylem water. We recommend the post‐processing correction as the first choice for analysis of samples of unknown contamination. Nevertheless, MCM can be more effective for evaluating samples containing contaminants responsible for strong spectral interferences at low concentrations, such as methanol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isotope-abundance variations of selected elements (IUPAC Technical Report)
Coplen, T. B., Böhlke, J. K., De Bièvre, P., Ding, T., Holden, N. E., Hopple, J. A., Krouse, H. R., Lamberty, A., Peiser, H. S., Revesz, K., et al. (2002) · Pure and Applied Chemistry · doi:10.1351/pac200274101987 · Cited by 437
Cited by
Deuterium‐ and Tritium‐Labelled Compounds: Applications in the Life Sciences
Atzrodt, J., Derdau, V., Kerr, W. J., & Reid, M. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201704146 · Cited by 810
Stable isotopes in leaf water of terrestrial plants
Cernusak, L. A., Barbour, M. M., Arndt, S. K., Cheesman, A. W., English, N. B., Feild, T. S., Helliker, B. R., Holloway‐Phillips, M. M., Holtum, J. A. M., Kahmen, A., et al. (2016) · Plant, Cell & Environment · doi:10.1111/pce.12703 · Cited by 379
Metadata
- Authors
- Martín‐Gómez, P., Barbeta, A., Voltas, J., Peñuelas, J., Dennis, K., Palacio, S., Dawson, T. E., & Ferrio, J. P.
- Venue
- New Phytologist
- Publisher
- Wiley
- Published
- 2015-03-19
- Volume
- 207
- Issue
- 3
- Pages
- 914-927
- ISSN
- 0028-646X (ISSN-L)
- 1469-8137
- OpenAlex
- W2131796603
- Cited by
- 178
- References
- 1
- FWCI
- 11.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.