CoChat

Acute His‐Bundle Injury Current during Permanent His‐Bundle Pacing Predicts Excellent Pacing Outcomes

VIJAYARAMAN, PUGAZHENDHI, DANDAMUDI, GOPI, WORSNICK, SARAH, ELLENBOGEN, KENNETH A. · 2015 · Pacing and Clinical Electrophysiology
Cited by 110

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Introduction: His‐bundle (HB) pacing (P) is a physiological alternative to right ventricular pacing (RVP), but is technically challenging and limited by higher pacing thresholds. Myocardial injury current (IC) recorded during right ventricular lead placement implies good tissue contact and is associated with low‐pacing thresholds. IC at the HB has not been previously described. We hypothesized that HBIC during permanent HBP may be associated with lower pacing thresholds. Methods: Permanent HBP was performed using Medtronic Select Secure tm (Medtronic Inc., Minneapolis, MN, USA) delivered via a fixed‐curve (C315 His) sheath. HB electrogram (EGM) was recorded in a unipolar fashion from the lead tip. Presence or absence of HBIC was documented. HBP threshold, sensing, and impedances were recorded at implant, 2 weeks, 2 months, and 1 year. Results: Sixty patients (age 72 ± 15 years; male 55%, sick sinus syndrome 40%, atrioventricular block 60%, fluoroscopy duration 9.2 ± 3.7 minutes) underwent successful permanent HBP. HBIC was recorded in 22 (37%) patients (group I). HBEGM without IC was recorded in the remaining 38 (63%) patients (group II). Pacing threshold at implant, 2 weeks, 2 months, and 1 year were significantly lower in group I (1.16 ± 0.4 V; 1.18 ± 0.5 V; 1.23 ± 0.6 V; 1.3 ± 0.6 V @ 0.5 ms) compared to group II (1.75 ± 0.7 V; 1.82 ± 0.8 V; 1.93 ± 0.8 V; 1.98 ± 0.9 V @ 0.5 ms, P < 0.05), respectively. Conclusions: IC can be recorded at the HB during permanent HBP in 37% of patients. HBIC is associated with significantly lower pacing thresholds compared to patients in whom HBIC was not recorded. HBIC may be a marker for superior short‐term HBP thresholds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/pace.12571

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 110

Metadata

Authors
VIJAYARAMAN, P., DANDAMUDI, G., WORSNICK, S., & ELLENBOGEN, K. A.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2015-01-14
Volume
38
Issue
5
Pages
540-546
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1580090814
Cited by
110
References
4
FWCI
10.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.