CoChat

New noninvasive approach assessing in vivo sun protection factor (SPF) using diffuse reflectance spectroscopy (DRS) and in vitro transmission

Ruvolo Junior, Eduardo, Kollias, Nikiforos, Cole, Curtis · 2014 · Photodermatology, Photoimmunology & Photomedicine
Cited by 42

The DOI matches its Crossref record.

Abstract

Summary: Background/Purpose: In the past 56 years, many different in vitro methodologies have been developed and published to assess the sun protection factor (SPF) of products, but there is no method that has 1 : 1 correlation with in vivo measurements. Spectroscopic techniques have been used to noninvasively assess the UVA protection factor with good correlation to in vivo UVA‐PF methodologies. To assess the SPF of sunscreen product by diffuse reflectance spectroscopy (DRS) technique, it is necessary to also determine the absorbance spectrum of the test material in the UVB portion of the spectrum (290–320 nm). However, because of the high absorbance characteristics of the stratum corneum and epidermis, the human skin does not remit enough UVB radiation to be used to measure the absorption spectrum of the applied product on skin. In this work, we present a new method combining the evaluation of the absolute UVA absorption spectrum, as measured by DRS with the spectral absorbance ‘shape’ of the UVB absorbance of the test material as determined with current in vitro thin film spectroscopy. Methods: The measurement of the in vivo UVA absorption spectrum involves the assessment of the remitted intensity of monochromatic UVA radiation (320–400 nm) before and after a sunscreen product was applied on skin using a spectrofluorimeter F luorolog 3, FL 3‐22 (Y von H oriba, E dison, NJ, USA). The probe geometry assures that light scattering products as well as colored products may be correctly assessed. This methodology has been extensively tested, validated, and reported in the literature. The in vitro absorption spectrum of the sunscreen samples and polyvinyl chloride (PVC) films ‘surrogate’ sunscreen standards were measured using Labsphere® UV‐2000S (L absphere, N orth S utton, NH, USA). Sunscreens samples were tested using PMMA H elioplates (H elioscience, M arseille, F rance) as substrates. The UVB absorbance spectrum (L absphere) is ‘attached’ to the UVA absorbance spectrum (diffuse reflectance) with the UVB absorbance matched to the UVA absorbance at 340 nm to complete the full spectral absorbance from which an estimate the SPF of the product can be calculated. Results: Seventeen test materials with known in vivo SPF values were tested. Two of the tested products were PVC sunscreen thin films with 10–15 micrometers thickness and were used to investigate the absorption spectrum of these films when applied on different reflectance surfaces. Similar to the human in vivo SPF test, the developed methodology suggests limiting the use on F itzpatrick skin phototypes I to III. The correlation of this new method with in vivo clinical SPF values was 0.98 (r2) with a slope of 1.007. Conclusion: This new methodology provides a new approach to determine SPF values without the extensive UV irradiation procedures (and biological responses) currently used to establish sunscreen efficacy. Further work will be conducted to establish methods for evaluation of products that are not photostable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/phpp.12105

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Ruvolo Junior, E., Kollias, N., & Cole, C.
Venue
Photodermatology, Photoimmunology & Photomedicine
Publisher
Wiley
Published
2014-02-19
Volume
30
Issue
4
Pages
202-211
ISSN
  • 0905-4383 (ISSN-L)
  • 1600-0781
OpenAlex
W1956023058
Cited by
42
References
0
FWCI
3.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.