The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Radial endobronchial ultrasound for the diagnosis of peripheral pulmonary lesions: Asystematic review and meta‐analysis
Open accessAbstract
Tissue diagnosis of peripheral pulmonary lesions ( PPLs ) can be challenging. In the past, flexible bronchoscopy was commonly performed for this purpose but its diagnostic yield is suboptimal. This has led to the development of new bronchoscopic modalities such as radial endobronchial ultrasound (R‐ EBUS ), electromagnetic navigation bronchoscopy ( ENB ) and virtual bronchoscopy ( VB ). We performed this meta‐analysis using data from previously published R‐ EBUS studies, to determine its diagnostic yield and other performance characteristics. Ovid MEDLINE and PubMed databases were searched for R‐ EBUS studies in September 2016. Diagnostic yield was calculated by dividing the number of successful diagnoses by the total number of lesions. Meta‐analysis was performed using MedCalc (Version 16.8). Inverse variance weighting was used to aggregate diagnostic yield proportions across studies. Publication bias was assessed using funnel plot and Duval and Tweedie's test. 57 studies with a total of 7872 lesions were included in the meta‐analysis. These were published between October 2002 and August 2016. Overall weighted diagnostic yield for R‐ EBUS was 70.6% (95% CI : 68–73.1%). The diagnostic yield was significantly higher for lesions >2 cm in size, malignant in nature and those associated with a bronchus sign on computerized tomography ( CT ) scan. Diagnostic yield was also higher when R‐ EBUS probe was within the lesion as opposed to being adjacent to it. Overall complication rate was 2.8%. This is the largest meta‐analysis performed to date, assessing the performance of R‐ EBUS for diagnosing PPLs . R‐ EBUS has a high diagnostic yield (70.6%) with a very low complication rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
The National Lung Screening Trial Research Team (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102873 · Cited by 11,064
MedCalc: a new computer program for medical statistics
Schoonjans, F., Zalata, A., Depuydt, C. E., & Comhaire, F. H. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01703-8 · Cited by 547
Ost, D. E., Ernst, A., Lei, X. J., Kovitz, K. L., Benzaquen, S., Diaz-Mendoza, J. I., Greenhill, S. R., Toth, J. W., Feller-Kopman, D. J., Puchalski, J. T., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201507-1332oc · Cited by 531
Risk Factors of Pneumothorax and Bleeding
Yeow, K.-M., Su, I.-H., Pan, K.-T., Tsay, P.-K., Lui, K.-W., Cheung, Y.-C., & Chou, A. S.-B. (2004) · Chest · doi:10.1378/chest.126.3.748 · Cited by 433
Steinfort, D. P., Khor, Y. H., Manser, R. L., & Irving, L. B. (2011) · European Respiratory Journal · doi:10.1183/09031936.00075310 · Cited by 418
Ishida, T., Asano, F., Yamazaki, K., Shinagawa, N., Oizumi, S., Moriya, H., Munakata, M., Nishimura, M., & for the Virtual Navigation in Japan (V-NINJA) trial group (2011) · Thorax · doi:10.1136/thx.2010.145490 · Cited by 263
Endobronchial Ultrasound-Driven Biopsy in the Diagnosis of Peripheral Lung Lesions
Paone, G., Nicastri, E., Lucantoni, G., Dello Iacono, R., Battistoni, P., D'Angeli, A. L., & Galluccio, G. (2005) · Chest · doi:10.1378/chest.128.5.3551 · Cited by 223
Metadata
- Authors
- Ali, M. S., Trick, W., Mba, B. I., Mohananey, D., Sethi, J., & Musani, A. I.
- Venue
- Respirology
- Publisher
- Wiley
- Published
- 2017-02-08
- Volume
- 22
- Issue
- 3
- Pages
- 443-453
- ISSN
- 1323-7799 (ISSN-L)
- 1440-1843
- OpenAlex
- W2603006267
- Cited by
- 278
- References
- 20
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radial endobronchial ultrasound for the diagnosis of peripheral pulmonary lesions: Asystematic review and meta‐analysis. https://app.cochat.ai/papers/10.1111/resp.12980
- The paper
- Ali, M. S., Trick, W., Mba, B. I., Mohananey, D., Sethi, J., & Musani, A. I. (2017). Radial endobronchial ultrasound for the diagnosis of peripheral pulmonary lesions: Asystematic review and meta‐analysis. Respirology. https://doi.org/10.1111/resp.12980
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.