Bedside Ultrasonography for Arteriovenous Fistula Cannulation
Abstract
Difficulty in accessing a new arteriovenous fistula (AVF) is a common technical issue in hemodialysis patients, which often leads to interventional radiology and/or vascular surgery referral. As a consequence, the patient who needs dialysis may require a temporary dialysis catheter with its known potential complications. We present a case where bedside ultrasonography facilitated successful cannulation of a difficult AVF. Ultrasonography (US) training in this procedure may allow early cannulation of new AVF s when the venous diameter is large enough (>0.6 cm) but the fistula is too deep (>0.6 cm). Real‐time, US‐guided AVF cannulation may also decrease the number of failed venous punctures per hemodialysis (HD) session minimizing vessel wall damage and subsequent potential hematoma and aneurysm formation.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The recommendation to use ultrasound guidance for central venous cannulation/insertion has been extrapolated to include real-time use with arteriovenous fistula cannulation.
“The recommendation to use ultrasound guidance for central venous cannulation/insertion has been extrapolated to include real-time use with AVF cannulation [35].”
From Improving vascular access outcomes: attributes of arteriovenous fistula cannulation success (2016) · cites this paper as [35]
Cited by
Sorted by citations
Improving vascular access outcomes: attributes of arteriovenous fistula cannulation success
Harwood, L. E., Wilson, B. M., & Oudshoorn, A. (2016) · Clinical Kidney Journal · doi:10.1093/ckj/sfv158 · Cited by 32 · see citing works
- Authors
- Patel, R. A., Stern, A. S., Brown, M., & Bhatti, S.
- Affiliations
- Icahn School of Medicine at Mount Sinai (US)
- Corresponding author
- Patel, Roshan A.
- Venue
- Seminars in Dialysis
- Publisher
- Wiley
- Published
- 2015-05-27
- Volume
- 28
- Issue
- 4
- Pages
- 433-434
- ISSN
- 0894-0959 (ISSN-L)
- 1525-139X
- OpenAlex
- W1870766710
- Cited by
- 25
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2022: 3 · 2021: 2 · 2020: 6 · 2019: 4 · 2018: 2 · 2017: 1 · 2016: 2
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Seminars in Dialysis (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Emergency Medical Services › Central Venous Catheters and Hemodialysis
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
- Keywords
- arteriovenous fistula, point-of-care ultrasound, ultrasound-guided cannulation, hemodialysis vascular access, vascular access complications, hematoma, aneurysm
- MeSH terms
- Point-of-Care Testing, Aged, Arteriovenous Shunt, Surgical, Catheterization, Renal Dialysis, Humans, Male, Ultrasonography, Interventional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review