Cited by 25Central Venous Catheters and HemodialysisUltrasound in Clinical ApplicationsVascular Procedures and Complications

Bedside Ultrasonography for Arteriovenous Fistula Cannulation

Patel, Roshan A., Stern, Aaron S., Brown, Maritza, Bhatti, Saad·2015·Seminars in Dialysis

Abstract

Difficulty in accessing a new arteriovenous fistula (AVF) is a common technical issue in hemodialysis patients, which often leads to interventional radiology and/or vascular surgery referral. As a consequence, the patient who needs dialysis may require a temporary dialysis catheter with its known potential complications. We present a case where bedside ultrasonography facilitated successful cannulation of a difficult AVF. Ultrasonography (US) training in this procedure may allow early cannulation of new AVF s when the venous diameter is large enough (>0.6 cm) but the fistula is too deep (>0.6 cm). Real‐time, US‐guided AVF cannulation may also decrease the number of failed venous punctures per hemodialysis (HD) session minimizing vessel wall damage and subsequent potential hematoma and aneurysm formation.

Integrity signals

Registry

Crossref · 10.1111/sdi.12394

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The recommendation to use ultrasound guidance for central venous cannulation/insertion has been extrapolated to include real-time use with arteriovenous fistula cannulation.

    “The recommendation to use ultrasound guidance for central venous cannulation/insertion has been extrapolated to include real-time use with AVF cannulation [35].”

Cited by

Sorted by citations

Authors
Patel, R. A., Stern, A. S., Brown, M., & Bhatti, S.
Affiliations
Icahn School of Medicine at Mount Sinai (US)
Corresponding author
Patel, Roshan A.
Venue
Seminars in Dialysis
Publisher
Wiley
Published
2015-05-27
Volume
28
Issue
4
Pages
433-434
ISSN
  • 0894-0959 (ISSN-L)
  • 1525-139X
OpenAlex
W1870766710
Cited by
25
References
0
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2022: 3 · 2021: 2 · 2020: 6 · 2019: 4 · 2018: 2 · 2017: 1 · 2016: 2
FWCI
2.87
Type
journal article
Language
en
Open access
closed
Locations
  • Seminars in Dialysis (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Emergency Medical Services › Central Venous Catheters and Hemodialysis
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
Keywords
arteriovenous fistula, point-of-care ultrasound, ultrasound-guided cannulation, hemodialysis vascular access, vascular access complications, hematoma, aneurysm
MeSH terms
Point-of-Care Testing, Aged, Arteriovenous Shunt, Surgical, Catheterization, Renal Dialysis, Humans, Male, Ultrasonography, Interventional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review