CoChat

Development of a riboflavin and ultraviolet light-based device to treat whole blood

Reddy, Heather L., Doane, Suzann K., Keil, Shawn D., Marschner, Susanne, Goodrich, Raymond P. · 2013 · Transfusion
Cited by 33

The DOI matches its Crossref record.

Abstract

Background: In the U nited S tates, blood components are commonly used for patients in need of massive transfusion after blood loss. In combat situations, when severe traumatic injuries occur far from a hospital, fresh whole blood is a valuable transfusion therapy because components may not be available. The risk of infectious or immunological complications from fresh whole blood transfusions could be mitigated by a system that reduces pathogen loads and inactivates white blood cells (WBCs). Such a system is in development and utilizes riboflavin and ultraviolet light to provide pathogen reduction and WBC inactivation. Study Design and Methods: The system has been tested with in vitro and in vivo animal studies to evaluate WBC inactivation and pathogen reduction, and with in vitro studies to assess the function of the treated blood products. Results: Elimination of viable WBCs with the system is equivalent to gamma‐irradiation. Results have been reported for reduction of B abesia microti, T rypanosoma cruzi, HIV, and bacteria, and preliminary results for B abesia divergens are available. Treated whole blood, platelets, and plasma maintain coagulation function. Treated red blood cell components exhibit low hemolysis and high adenosine triphosphate levels at the end of storage. Conclusions: Treatment with riboflavin and ultraviolet light is a promising alternative to gamma‐irradiation. Effectiveness of the system against a variety of pathogens has been established, and further studies are planned. The in vitro studies of function indicate that treated whole blood, as well as components from treated whole blood, will provide acceptable hemostasis and perform well in the next phase of in vivo studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/trf.12047

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 22

  1. 10.1016/j.tmrv.2007.12.003 · DOI
  2. 10.1111/j.1537-2995.2010.02694.x · DOI
  3. Council of Europe, 2010, Guide to the preparation, use, and quality assurance of blood components
  4. 10.1111/j.1537‐2995.2012.03715.x · DOI
  5. 10.1111/j.1537‐2995.2012.03791.x · doi:10.1111/j.1537-2995.2012.03791.x
  6. 10.1111/j.1537-2995.2009.02538.x · doi:10.1111/j.1537-2995.2009.02538.x
  7. Sullivan JJ, 2008, Pathogen inactivation of plasmodium falciparum in plasma and platelet concentrates with riboflavin and UV light. 30th International Congress of the ISBT, Macao, SAR, China, June 7‐12, 2008, Vox Sang, 95, 278
  8. Kiser P, 2012, Mirasol pathogen reduction technology (PRT) treatment of P. yoelii contaminated plasma neutralized parasite in a murine model for malaria, Vox Sang, 103, 136
  9. 10.1111/j.1537-2995.2010.02635.x · doi:10.1111/j.1537-2995.2010.02635.x
  10. Organización Panamericana de la Salud, 2006, Estimación cuantitativa de la enfermedad de Chagas en las Americas. Document OPS/HDM/CD/425‐06
  11. 10.1046/j.1537-2995.2002.00077.x · doi:10.1046/j.1537-2995.2002.00077.x
  12. 10.1111/j.1537-2995.2011.03285.x · doi:10.1111/j.1537-2995.2011.03285.x
  13. 10.1159/000324160 · doi:10.1159/000324160
  14. 10.1016/j.biologicals.2009.10.016 · doi:10.1016/j.biologicals.2009.10.016
  15. Keil S, 2012, Viral reduction of intracellular HIV using the Mirasol system for whole blood, Vox Sang, 103, 144
  16. Pidcoke HF, 2011, Whole blood stored at four degrees retains platelet function, normal prothrombin time and overall hemostatic function as measured by thromboelastography, Transfusion, 51, SP8
  17. 10.1111/trf.12048 · DOI
  18. 10.1046/j.1537-2995.1998.38198141495.x · doi:10.1046/j.1537-2995.1998.38198141495.x
  19. 10.1111/j.1537-2995.2010.03027.x · doi:10.1111/j.1537-2995.2010.03027.x
  20. Doane SK, 2012, Storage of packed red blood cells derived from whole blood treated with the Mirasol system, Vox Sang, 103, 143
  21. 10.1046/j.1537-2995.1999.39299154725.x · doi:10.1046/j.1537-2995.1999.39299154725.x
  22. 10.1111/j.1365-3148.2006.00679.x · doi:10.1111/j.1365-3148.2006.00679.x

Cited by

Metadata

Authors
Reddy, H. L., Doane, S. K., Keil, S. D., Marschner, S., & Goodrich, R. P.
Affiliations
Terumo BCT Biotechnologies LLC Lakewood Colorado
Venue
Transfusion
Publisher
Wiley
Published
2013-01
Volume
53
Issue
S1
ISSN
  • 0041-1132
  • 1537-2995
Cited by
33
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.