CoChat

When blood transfusion medicine becomes complicated due to interference by monoclonal antibody therapy

Open access
Oostendorp, Marlies, Lammerts van Bueren, Jeroen J., Doshi, Parul, Khan, Imran, Ahmadi, Tahamtan, Parren, Paul W.H.I., van Solinge, Wouter W., De Vooght, Karen M.K. · 2015 · Transfusion
Cited by 161

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Monoclonal antibodies (MoAbs) are increasingly integrated in the standard of care. The notion that therapeutic MoAbs can interfere with clinical laboratory tests is an emerging concern that requires immediate recognition and the development of appropriate solutions. Here, we describe that treatment of multiple myeloma patients with daratumumab, a novel anti‐CD38 MoAb, resulted in false‐positive indirect antiglobulin tests (IATs) for all patients for 2 to 6 months after infusion. This precluded the correct identification of irregular blood group antibodies for patients requiring blood transfusion. STUDY DESIGN AND METHODS: The IAT was performed using three‐ and 11‐donor‐cell panels. Interference of daratumumab and three other anti‐CD38 MoAbs was studied using fresh‐frozen plasma spiked with different MoAb concentrations. Additionally it was tested whether two potentially neutralizing agents, anti‐idiotype antibody and recombinant soluble CD38 (sCD38) extracellular domain, were able to inhibit the interference. RESULTS: The CD38 MoAbs caused agglutination in the IAT in a dose‐dependent manner. Addition of an excess of anti‐idiotype antibodies or sCD38 protein to the test abrogated CD38 MoAb interference and successfully restored irregular antibody screening and identification. DISCUSSION: CD38 MoAb therapy causes false‐positive results in the IAT. The reliability of the test could be restored by adding a neutralizing agent against the CD38 MoAb to the patient's plasma. This study emphasizes that during drug development, targeted therapeutics should be investigated for potential interference with laboratory tests. Clinical laboratories should be informed when patients receive MoAb treatments and matched laboratory tests to prevent interference should be employed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/trf.13150

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

Metadata

Authors
Oostendorp, M., Lammerts van Bueren, J. J., Doshi, P., Khan, I., Ahmadi, T., Parren, P. W. H. I., van Solinge, W. W., & De Vooght, K. M. K.
Venue
Transfusion
Publisher
Wiley
Published
2015-05-18
Volume
55
Issue
6pt2
Pages
1555-1562
ISSN
  • 0041-1132 (ISSN-L)
  • 1537-2995
OpenAlex
W1706622670
Cited by
161
References
12
FWCI
14.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.