CoChat

Severe CD4+ T-cell lymphopenia is not observed in frequent plateletpheresis donors collected on the Fenwal Amicus

Gansner, John M., Papari, Mona, Goldstein, Jake, Gaufberg, Rachel A., Neuberg, Donna, Makar, Robert S., Kaufman, Richard M. · 2019 · Transfusion
Cited by 9

The DOI matches its Crossref record.

Abstract

BACKGROUND: In a recent study, we determined that 30% of frequent plateletpheresis donors collected using the Trima Accel Automated Blood Collection System (Terumo BCT) had a CD4+ T‐cell count below 200 cells/μL. Whether CD4+ T‐cell lymphopenia is associated with donation using other plateletpheresis instruments is unknown. STUDY DESIGN AND METHODS: We obtained blood samples from 30 current frequent Fenwal Amicus plateletpheresis donors. All participants had made 20 to 24 plateletpheresis donations in the most recent 365‐day period, and all had previously donated over 50 times on the Fenwal Amicus instrument. Blood samples were analyzed to determine blood counts, including CD4+ and CD8+ counts. RESULTS: Of 30 study participants, none had a CD4+ count below 200 cells/μL. There was one participant with a CD4+ count between 200 and 300 cells/μL. This individual was over the age of 55 and had a history of more than 300 lifetime plateletpheresis sessions. One participant had a CD8+ count below the lower limit of normal (125 cells/μL) and a normal CD4+ count. CONCLUSION: We did not detect severe CD4+ lymphopenia in frequent platelet donors undergoing plateletpheresis with the Fenwal Amicus. Since the Fenwal Amicus does not incorporate a leukoreduction system chamber, this finding supports the hypothesis that such chambers—found in the Trima Accel instrument—contribute to CD4+ lymphopenia in frequent platelet donors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/trf.15441

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 4

  1. 10.1182/blood-2018-09-873125 · DOI · Paper page
  2. 10.1111/trf.15192 · DOI · Paper page
  3. 10.1111/trf.14616 · doi:10.1111/trf.14616
  4. 10.1046/j.0902-4441.2003.00199.x · DOI · Paper page

Cited by

Metadata

Authors
Gansner, J. M., Papari, M., Goldstein, J., Gaufberg, R. A., Neuberg, D., Makar, R. S., & Kaufman, R. M.
Affiliations
  • Hematology Division Brigham and Women's Hospital Boston Massachusetts
  • Vitalant Rosemount Illinois
  • Department of Biostatistics and Computational Biology Dana‐Farber Cancer Institute Boston Massachusetts
  • Department of Pathology Massachusetts General Hospital Boston Massachusetts
  • Department of Pathology Brigham and Women's Hospital Boston Massachusetts
Venue
Transfusion
Publisher
Wiley
Published
2019-07-04
Volume
59
Issue
9
Pages
2783-2787
ISSN
  • 0041-1132
  • 1537-2995
Cited by
9
References
0
Language
en
Funders
  • National Heart, Lung, and Blood Institute (HL087164)
  • National Cancer Institute (5P30 CA006516)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.