Risk factors for T‐cell lymphopenia in frequent platelet donors: The BEST collaborative study
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Severe T‐cell lymphopenia of uncertain clinical significance has been observed in frequent apheresis platelet donors. Two commonly used plateletpheresis instruments are the Trima Accel, which uses a leukoreduction system (LRS) chamber to trap leukocytes and the Fenwal Amicus, which does not use an LRS chamber. Study Design and Methods: We performed an international, multicenter, observational study comparing T‐cell populations in frequent platelet donors collected exclusively using the Trima instrument ( n = 131) or the Amicus instrument ( n = 77). Age‐ and sex‐matched whole blood donors ( n = 126) served as controls. Results: CD4 + T‐cell counts <200 cells/μL were found in 9.9% of frequent Trima (LRS+) platelet donors, 4.4% of frequent Amicus (LRS−) platelet donors, and 0 whole blood donors ( p < .0001). CD4 + T‐cell counts <200 cells/μL were only seen in platelet donors with ≥200 lifetime donations. In multivariable analysis, age, lifetime donations, and instrument (Trima vs. Amicus) were independent risk factors for lymphopenia. In 40 Trima platelet donors, a plasma rinseback procedure was routinely performed following platelet collections. No Trima platelet donors receiving plasma rinseback had a CD4 + T‐cell count <200 cells/μL versus 13/91 Trima platelet donors not receiving plasma rinseback ( p = .01). Discussion: Recurrent bulk lymphocyte removal appears to contribute to the development of T‐cell lymphopenia in frequent, long‐term platelet donors. Lymphopenia is more common when an LRS chamber is used during platelet collection but can occur without an LRS chamber. Blood centers using LRS chambers can mitigate donor lymphopenia by performing plasma rinseback.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Technological optimisation—specifically, preferential procurement of apheresis platforms without LRS chambers, or implementation of plasma rinseback protocols that partially restore lymphocytes to the donor—can substantially reduce lymphocyte loss without compromising platelet yield”
From Potential Health Consequences of Regular Blood Donation: Current Evidence and Remaining Uncertainties (2026) · cites this paper as [24]
In the citing paper
“The BEST collaborative study confirmed these findings across multiple international centres, documenting CD4+ below 200 cells/µL in 9.9% of frequent Trima donors versus 4.4% of Amicus donors versus 0% of whole blood donor controls”
From Potential Health Consequences of Regular Blood Donation: Current Evidence and Remaining Uncertainties (2026) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human T cell development, localization, and function throughout life
Kumar, B. V., Connors, T. J., & Farber, D. L. (2018) · Immunity · doi:10.1016/j.immuni.2018.01.007 · Cited by 1,257
The twilight of immunity: emerging concepts in aging of the immune system
Nikolich-Žugich, J. (2018) · Nature Immunology · doi:10.1038/s41590-017-0006-x · Cited by 1,240
Jones, J. M., Sapiano, M. R. P., Mowla, S., Bota, D., Berger, J. J., & Basavaraju, S. V. (2021) · Transfusion · doi:10.1111/trf.16449 · Cited by 121
Research works printed but not linked: 18
- 10.1182/blood-2018-09-873125 · DOI · Paper page
- 10.1111/trf.16666 · doi:10.1111/trf.16666
- 10.1111/trf.15441 · DOI · Paper page
- Kelly K, 2022, Characterization of residual cell populations in leukoreduction system (LRS) disposable sets following apheresis platelet collections, Transfusion, 62, 29A
- 10.1016/j.xcrm.2022.100893 · DOI
- 10.1111/j.1537-2995.2006.01033.x · DOI · Paper page
- 10.1371/journal.pmed.1002685 · DOI · Paper page
- 10.1001/jamanetworkopen.2019.16526 · DOI
- 10.1111/trf.16373 · doi:10.1111/trf.16373
- 10.1111/trf.16175 · DOI · Paper page
- 10.1111/trf.17037 · DOI · Paper page
- Desjardin M, 2023, Immunogenicity of quadrivalent meningococcal conjugate vaccine in frequent platelet donors, Blood, 142, 202
- 10.1056/NEJMoa2202348 · DOI
- 10.1046/j.1537-2995.1992.32192116433.x · doi:10.1046/j.1537-2995.1992.32192116433.x
- 10.1002/ajh.25817 · DOI
- 10.1111/imr.12693 · DOI · Paper page
- 10.1002/cyto.10084 · doi:10.1002/cyto.10084
- 10.1002/cyto.b.20370 · DOI
Cited by
Berli, S., Kaiser, M. S., Schindler, E., & Tsakiris, D. A. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15176847
“Although in some studies recurrent viral infections were associated with the severity of lymphopenia [25], in others no differences in seroresponsiveness after vaccinations were noticed [24,27].”
Influential
Metadata
- Authors
- Kaufman, R. M., Marks, D. C., Flamand, Y., Acker, J. P., Brown, B. L., Olafson, C., Marschner, S., Pandey, S., Papari, M., Petraszko, T., Serrano, K., Ward, D., Bazin, R., & Collaborative, F. T. B. E. F. S. T.
- Affiliations
- Department of Pathology Brigham and Women's Hospital and Harvard Medical School Boston Massachusetts USA
- Research and Development Australian Red Cross Lifeblood Sydney New South Wales Australia
- Department of Data Science Dana‐Farber Cancer Institute Boston Massachusetts USA
- Medical Affairs and Innovation Canadian Blood Services Ottawa Ontario Canada
- American Red Cross Biomedical Services, Medical and Scientific Office Washington DC USA
- Vitalant Rosemont Illinois USA
- Department of Pathology Stanford University School of Medicine and Stanford Blood Center Palo Alto California USA
- Wing‐Kwai and Alice Lee‐Tsing Chung Transfusion Service, Department of Pathology and Laboratory Medicine David Geffen School of Medicine at UCLA Los Angeles California USA
- Héma‐Québec, Medical Affairs and Innovation Quebec City Quebec Canada
- ORCID
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2023-10-11
- Volume
- 63
- Issue
- 11
- Pages
- 2072-2082
- ISSN
- 0041-1132
- 1537-2995
- Cited by
- 9
- References
- 3
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.