Validity of glycated haemoglobin to diagnose new onset diabetes after transplantation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Diagnosing new onset diabetes after transplantation (NODAT) by glycated haemoglobin (HbA1c) has not been validated against the gold-standard oral glucose tolerance test (OGTT). We analysed the predictive and optimum value of HbA1c to diagnose NODAT amongst nondiabetic renal transplant recipients. Assessment of glucose metabolism (OGTT and HbA1c) was prospectively undertaken at 3 and 12 months post-transplantation in 71 nondiabetic renal transplant recipients. Receiver operator characteristic (ROC) curve analyses were performed to determine accuracy, sensitivity, specificity and area under curve (c-statistic). Incidence of NODAT at 3 and 12 months post-transplantation was 14.3% and 9.5% respectively. At 3 months, optimum HbA1c cut-off value for predicting NODAT based on fasting glucose was 7.35 [AUC 1.00 (sensitivity 100.0%, specificity 100.0%, P = 0.004)] and for postprandial glucose-defined NODAT was 6.20 [AUC 0.98 (sensitivity 100.0%, specificity 88.9%, P < 0.001)]. At 12 months, optimum HbA1c cut-off value for both fasting- and postprandial glucose-defined NODAT was 6.45 [AUC 0.92 (sensitivity 100.0%, specificity 87.5%, P = 0.048) and AUC 0.84 (sensitivity 75.0%, specificity 89.5%, P = 0.026) respectively]. Concordance between diagnosis of NODAT (OGTT+, HbA1c+) and nondiagnosis of NODAT (OGTT-, HbA1c-) was 88.9% and 98.7% respectively. To conclude, HbA1c (≥6.5%) can be utilized to diagnose NODAT beyond 3 months post-transplantation but the OGTT remains the gold-standard tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of medical care in diabetes—2011
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s011 · Cited by 2,880
Cited by
Sharif, A., Hecking, M., de Vries, A. P. J., Porrini, E., Hornum, M., Rasoul-Rockenschaub, S., Berlakovich, G., Krebs, M., Kautzky-Willer, A., Schernthaner, G., et al. (2014) · American Journal of Transplantation · doi:10.1111/ajt.12850 · Cited by 532
“Shabir et al (22) suggest optimum HbA1c cut-off values for predicting PTDM at 3 and 12 months of 44mmol/mol (6.”
BackgroundInfluentialPost-Transplant Diabetes Mellitus: Causes, Treatment, and Impact on Outcomes
Shivaswamy, V., Boerner, B., & Larsen, J. (2016) · Endocrine Reviews · doi:10.1210/er.2015-1084 · Cited by 328
Diabetes Care After Transplant
Wallia, A., Illuri, V., & Molitch, M. E. (2016) · Medical Clinics of North America · doi:10.1016/j.mcna.2016.01.005 · Cited by 50
Hyperglycemia management in patients with posttransplantation diabetes
Galindo, R. J., Fried, M., Breen, T., & Tamler, R. (2016) · Endocrine Practice · doi:10.4158/ep151039.ra · Cited by 25
Metadata
- Authors
- Shabir, S., Jham, S., Harper, L., Ball, S., Borrows, R., & Sharif, A.
- Venue
- Transplant International
- Publisher
- Frontiers Media SA
- Published
- 2013-01-02
- Volume
- 26
- Issue
- 3
- Pages
- 315-321
- ISSN
- 0934-0874 (ISSN-L)
- OpenAlex
- W2017820983
- Cited by
- 74
- References
- 1
- FWCI
- 6.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.