ASVCP guidelines: allowable total error guidelines for biochemistry
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
As all laboratory equipment ages and contains components that may degrade with time, initial and periodically scheduled performance assessment is required to verify accurate and precise results over the life of the instrument. As veterinary patients may present to general practitioners and then to referral hospitals (both of which may each perform in‐clinic laboratory analyses using different instruments), and given that general practitioners may send samples to reference laboratories, there is a need for comparability of results across instruments and methods. Allowable total error (TEa) is a simple comparative quality concept used to define acceptable analytical performance. These guidelines are recommendations for determination and interpretation of TEa for commonly measured biochemical analytes in cats, dogs, and horses for equipment commonly used in veterinary diagnostic medicine.TEa values recommended herein are aimed at all veterinary settings, both private in‐clinic laboratories using point‐of‐care analyzers and larger reference laboratories using more complex equipment. They represent the largest TE a possible without generating laboratory variation that would impact clinical decision making.TEa can be used for (1) assessment of an individual instrument's analytical performance, which is of benefit if one uses this information during instrument selection or assessment of in‐clinic instrument performance, (2) Quality Control validation, and (3) as a measure of agreement or comparability of results from different laboratories (eg, between the in‐clinic analyzer and the reference laboratory). These guidelines define a straightforward approach to assessment of instrument analytical performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tietz Textbook of Clinical Chemistry and Molecular Diagnostics
Burtis, E. B. C. A., Ashwood, E. R., & Bruns, D. E. (2011) · Medical Entomology and Zoology · Cited by 2,190
Biostatistics : The Bare Essentials
Norman, G. R., & Streiner, D. L. (1993) · Cited by 1,482
Friedrichs, K. R., Harr, K. E., Freeman, K. P., Szladovits, B., Walton, R. M., Barnhart, K. F., & Blanco‐Chavez, J. (2012) · Veterinary Clinical Pathology · doi:10.1111/vcp.12006 · Cited by 1,293
Self-citationBiological Variation: From Principles to Practice
Fraser, C. G. (2001) · Cited by 653
Clinical Chemistry of Companion Avian Species: A Review
Harr, K. E. (2002) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2002.tb00295.x · Cited by 406
Self-citationProposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400103 · Cited by 370
Hucthins, D. (1998) · Australian Veterinary Journal · doi:10.1111/j.1751-0813.1998.tb10197.x · Cited by 360
Method comparison in the clinical laboratory
Jensen, A. L., & Kjelgaard‐Hansen, M. (2006) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2006.tb00131.x · Cited by 341
Fundamentals of Veterinary Clinical Pathology
Papasouliotis, K. (2003) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2003.tb00330.x · Cited by 257 · cited 1×
“For the purpose of this document, we define TEa as bias (%) + 2CV(%) which is consistent with CLIA recommendations.(7) If units of the test are used, then the equation, bias (expressed in units of the test) + 2 Standard Deviations (SD), is used to calculate absolute TEa.”
Criteria for judging precision and accuracy in method development and evaluation
Westgard, J. O., Carey, R. N., & Wold, S. (1974) · Clinical Chemistry · doi:10.1093/clinchem/20.7.825 · Cited by 236
Cited by
Renal biomarkers in domestic species
Hokamp, J. A., & Nabity, M. B. (2016) · Veterinary Clinical Pathology · doi:10.1111/vcp.12333 · Cited by 191
Self-citationKarapinar, T., Tumer, K. C., & Buczinski, S. (2020) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.15794 · Cited by 11
“The performance of the Freestyle Optium Neo H was also assessed using a calculation of TEobs as follows: TEobs = 2 × intra-assay CV (%) + bias (%).(23) The bias was calculated according to the formula: bias% = [(reference method − glucometer)/reference method] × 100.”
MethodEvaluation of the i-STAT Alinity v in a veterinary clinical setting
Burke, J. E., Nguyen, T. H. T., Davis, T., Koenig, A., Lane, S. L., Good, J., & Brainard, B. M. (2021) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/10406387211019710 · Cited by 9
“Under ideal study conditions, the total observable error (TEo) would have been calculated during the precision studies.(5) Generally, TEo (calculated as bias + 2 CV) is calculated from the CV of 20 replicate assessments of a single sample.”
Method
Metadata
- Authors
- Harr, K. E., Flatland, B., Nabity, M., & Freeman, K. P.
- Venue
- Veterinary Clinical Pathology
- Publisher
- Wiley
- Published
- 2013-12
- Volume
- 42
- Issue
- 4
- Pages
- 424-436
- ISSN
- 0275-6382 (ISSN-L)
- 1939-165X
- OpenAlex
- W2025856846
- Cited by
- 227
- References
- 19
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ASVCP guidelines: allowable total error guidelines for biochemistry. https://app.cochat.ai/papers/10.1111/vcp.12101
- The paper
- Harr, K. E., Flatland, B., Nabity, M., & Freeman, K. P. (2013). ASVCP guidelines: allowable total error guidelines for biochemistry. Veterinary Clinical Pathology. https://doi.org/10.1111/vcp.12101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.