CoChat

Vascular responsiveness determined by near‐infrared spectroscopy measures of oxygen saturation

Open access
McLay, Kaitlin M., Fontana, Federico Y., Nederveen, Josh P., Guida, Federico F., Paterson, Donald H., Pogliaghi, Silvia, Murias, Juan M. · 2016 · Experimental Physiology
Cited by 127

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

New Findings: What is the central question of this study? Can the near‐infrared spectroscopy (NIRS)‐derived reperfusion rate (slope 2) of tissue oxygen saturation (S tO 2) be correlated with flow‐mediated dilation (FMD), the commonly used method to assess vascular endothelial function? What is the main finding and its importance? The present data were able to establish a correlation between the reperfusion rate of S tO 2 and percentage FMD in healthy young men. These data suggest that NIRS‐derived slope 2 S tO 2 can be used as a measure of vascular endothelial function. Vascular impairments at the macro‐ and microcirculatory levels are associated with increased risk for cardiovascular disease. Flow‐mediated dilation (FMD) is currently the most widely used method for non‐invasive assessment of vascular endothelial function. Recently, near‐infrared spectroscopy (NIRS)‐derived measures of tissue oxygen saturation (S tO 2) have been used to characterize the dynamic response of local tissue perfusion to a brief period of ischaemia. The purpose of the present study was to establish correlations between the reperfusion rate of S tO 2 and FMD. Ultrasound‐derived FMD was quantified after 5 min of distal cuff occlusion of the popliteal artery in 20 healthy young men (26 ± 3 years old). Triplicate measurements of end‐diastolic arterial diameter were made every 15 s after cuff release, and FMD response was calculated as the greatest percentage change in diameter from baseline (%FMD). The S tO 2 was measured using NIRS throughout the duration of each test. Two consecutive FMD tests were performed, separated by 30 min of rest, and were averaged for %FMD and S tO 2. The %FMD was significantly correlated with the reperfusion slope of S tO 2 after cuff release (slope 2 S tO 2; r = 0.63, P = 0.003). In conclusion, the present study established a correlation between slope 2 S tO 2 and %FMD in healthy young men. These data suggest that NIRS‐derived slope 2 S tO 2 can be used as a measure of vascular endothelial function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/ep085406

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 127

Metadata

Authors
McLay, K. M., Fontana, F. Y., Nederveen, J. P., Guida, F. F., Paterson, D. H., Pogliaghi, S., & Murias, J. M.
Venue
Experimental Physiology
Publisher
Wiley
Published
2015-12-06
Volume
101
Issue
1
Pages
34-40
ISSN
  • 0958-0670 (ISSN-L)
  • 1469-445X
OpenAlex
W1963124203
Cited by
127
References
3
FWCI
6.47
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vascular responsiveness determined by near‐infrared spectroscopy measures of oxygen saturation. https://app.cochat.ai/papers/10.1113/ep085406
The paper
McLay, K. M., Fontana, F. Y., Nederveen, J. P., Guida, F. F., Paterson, D. H., Pogliaghi, S., & Murias, J. M. (2016). Vascular responsiveness determined by near‐infrared spectroscopy measures of oxygen saturation. Experimental Physiology. https://doi.org/10.1113/ep085406

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.