CoChat

Human critical power–oxygen uptake relationship at different pedalling frequencies

Open access
Barker, Tyler, Poole, David C., Noble, M. Larry, Barstow, Thomas J. · 2006 · Experimental Physiology
Cited by 106

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Critical power (CP) is lower at faster rather than slower pedalling frequencies and traditionally reported in watts (W). Faster pedalling frequencies also engender a greater metabolic rate at low work rates, but with progressive increases in power output, the initial difference in between fast and slower pedalling frequencies is reduced. We tested the hypothesis that CP represents a unique metabolic rate for any given individual which would be similar at different pedalling frequencies. Eleven collegiate athletes (five cross‐country runners, END; six sprinters, SPR), aged 18–23 years, performed exhaustive rides at either 60 or 100 r.p.m. on separate days for the determination of the pedal rate‐specific CP. The at CP (CP‐ ) was determined from an 8 min ride at the CP for each pedal frequency. The group mean CP was significantly lower at 100 r.p.m. (189 ± 50 W) compared to 60 r.p.m. (207 ± 53 W, P < 0.05). However, the group mean CP‐ values at 60 (2.53 ± 0.60 l min−1) and 100 r.p.m. (2.58 ± 0.53 l min−1) were not significantly different. Critical power was significantly higher in the END athletes (242 ± 50 W at 60 r.p.m.; 221 ± 56 W at 100 r.p.m.) compared to SPR athletes at both pedal frequencies (177 ± 38 W at 60 r.p.m.; 162 ± 27 W at 100 r.p.m., P < 0.05), but the CP‐ was not (P > 0.05). However, when the CP‐ was scaled to body weight, the END athletes had a significantly greater CP‐ (41.3 ± 4.1 ml min−1 kg−1 at 60 r.p.m.; 40.8 ± 5.5 ml min−1 kg−1 at 100 r.p.m.) compared to the SPR athletes at both pedal frequencies (27.7 ± 4.6 ml min−1 kg−1 at 60 r.p.m.; 29.4 ± 2.8 ml min−1 kg−1 at 100 r.p.m., P < 0.05). We conclude that CP represents a specific metabolic rate which can be achieved at different combinations of power outputs and pedalling frequencies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/expphysiol.2005.032789

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 106

Metadata

Authors
Barker, T., Poole, D. C., Noble, M. L., & Barstow, T. J.
Venue
Experimental Physiology
Publisher
Wiley
Published
2006-04-24
Volume
91
Issue
3
Pages
621-632
ISSN
  • 0958-0670 (ISSN-L)
  • 1469-445X
OpenAlex
W1567812372
Cited by
106
References
4
FWCI
3.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human critical power–oxygen uptake relationship at different pedalling frequencies. https://app.cochat.ai/papers/10.1113/expphysiol.2005.032789
The paper
Barker, T., Poole, D. C., Noble, M. L., & Barstow, T. J. (2006). Human critical power–oxygen uptake relationship at different pedalling frequencies. Experimental Physiology. https://doi.org/10.1113/expphysiol.2005.032789

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.