Modelflow estimates of cardiac output compared with Doppler ultrasound during acute changes in vascular resistance in women
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We compared Modelflow (MF) estimates of cardiac stroke volume (SV) from the finger pressure‐pulse waveform (Finometer®) with pulsed Doppler ultrasound (DU) of the ascending aorta during acute changes in total peripheral resistance (TPR) in the supine and head‐up‐tilt (HUT) postures. Twenty‐four women were tested during intravenous infusion of 0.005 or 0.01 μg kg−1 min−1 isoprenaline, 10 or 50 ng kg−1 min−1 noradrenaline and 0.3 mg sublingual nitroglycerine. Responses to static hand‐grip exercise (SHG), graded lower body negative pressure (LBNP, from −20 to −45 mmHg) and 45 deg HUT were evaluated on separate days. Bland–Altman analysis indicated that SV MF yielded lower estimates than SV DU during infusion of 0.01 μg kg−1 min−1 isoprenaline (SV MF 92.7 ± 15.5 versus SV DU 104.3 ± 22.9 ml,P= 0.03) and SHG (SV MF 78.8 ± 12.0 versus SV DU 106.1 ± 28.5 ml,P< 0.01), while larger estimates were recorded with SV MF during −45 mmHg LBNP (SV MF 52.6 ± 10.7 versus SV DU 46.2 ± 14.5 ml,P= 0.04) and HUT (SV MF 59.3 ± 13.6 versus SV DU 45.2 ± 11.3 ml,P< 0.01). Linear regression analysis revealed a relationship (r2= 0.41,P< 0.01) between the change in TPR from baseline and the between‐methods discrepancy in SV measurements. This relationship held up under all of the experimental protocols (regression for fixed effects,P= 0.46). These results revealed a discrepancy in MF estimates of SV, in comparison with those measured by DU, during acute changes in TPR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Gisolf, J., Westerhof, B. E., van Dijk, N., Wesseling, K. H., Wieling, W., & Karemaker, J. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.038 · Cited by 59 · cited 1×
“Total peripheral resistance did not change with administration of NG, suggesting that there was vasoconstrictor compensation in the peripheral vasculature, probably mediated by the sympathetic nervous system (Gisolf et al. 2004).”
Background
Cited by
Fairfax, S. T., Padilla, J., Vianna, L. C., Davis, M. J., & Fadel, P. J. (2013) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00842.2012 · Cited by 144
Fairfax, S. T., Holwerda, S. W., Credeur, D. P., Zuidema, M. Y., Medley, J. H., Dyke II, P. C., Wray, D. W., Davis, M. J., & Fadel, P. J. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2013.250894 · Cited by 108
“software (Dyson et al. 2010; Kim et al. 2012), and aligned with LabVIEW program output via changes in cardiac interval.”
MethodVranish, J. R., Holwerda, S. W., Young, B. E., Credeur, D. P., Patik, J. C., Barbosa, T. C., Keller, D. M., & Fadel, P. J. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10229 · Cited by 98
Stewart, J. M., Pianosi, P., Shaban, M. A., Terilli, C., Svistunova, M., Visintainer, P., & Medow, M. S. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.118.008854 · Cited by 55
“Beat-to-beat BP was monitored using finger arterial plethysmography (Finometer; FMS, Amsterdam, the Netherlands) on the right middle or index finger and corrected for tilt angle, using ModelFlow software.(26) Finometer data were calibrated to brachial artery pressure and intermittently checked against oscillometric BP…”
MethodDel Pozzi, A. T., Schwartz, C. E., Tewari, D., Medow, M. S., & Stewart, J. M. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02824 · Cited by 49
Metadata
- Authors
- Dyson, K. S., Shoemaker, J. K., Arbeille, P., & Hughson, R. L.
- Venue
- Experimental Physiology
- Publisher
- Wiley
- Published
- 2010-03-16
- Volume
- 95
- Issue
- 4
- Pages
- 561-568
- ISSN
- 0958-0670 (ISSN-L)
- 1469-445X
- OpenAlex
- W2120653792
- Cited by
- 69
- References
- 2
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.