CoChat

Slowed oxygen uptake kinetics in hypoxia correlate with the transient peak and reduced spatial distribution of absolute skeletal muscle deoxygenation

Open access
Bowen, T. Scott, Rossiter, Harry B., Benson, Alan P., Amano, Tatsuro, Kondo, Narihiko, Kowalchuk, John M., Koga, Shunsaku · 2013 · Experimental Physiology
Cited by 66

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

New findings: What is the central question of the study? Does a transient overshoot in skeletal muscle deoxygenation (reflecting a kinetic mismatch of microvascular O 2 delivery to consumption) and/or its spatial distribution slow the adjustment of oxidative energy provision at the onset of exercise? What is the main finding and its importance? Slowed oxidative energy provision at the onset of exercise was correlated with the transient skeletal muscle deoxygenation peak and the reduced spatial distribution, measured by quantitative near‐infrared spectroscopy. It was not correlated with a microvascular O 2 delivery‐to‐consumption mismatch per se. This suggests that an absolute, rather than kinetic, mismatch of microvascular O 2 delivery and consumption limits the kinetics of muscular oxidative energy provision, but only when muscle deoxygenation reaches some ‘critical’ level. It remains unclear whether an overshoot in skeletal muscle deoxygenation (HHb; reflecting a microvascular kinetic mismatch of O 2 delivery to consumption) contributes to the slowed adjustment of oxidative energy provision at the onset of exercise. We progressively reduced the fractional inspired O 2 concentration () to investigate the relationship between slowed pulmonary O 2 uptake () kinetics and the dynamics and spatial distribution of absolute [HHb]. Seven healthy men performed 8 min cycling transitions during normoxia (), moderate hypoxia () and severe hypoxia (). uptake was measured using a flowmeter and gas analyser system. Absolute [HHb] was quantified by multichannel, time‐resolved near‐infrared spectroscopy from the rectus femoris and vastus lateralis (proximal and distal regions), and corrected for adipose tissue thickness. The phase II time constant was slowed (P < 0.05) as decreased (normoxia, 17 ± 3 s; moderate hypoxia, 22 ± 4 s; and severe hypoxia, 29 ± 9 s). The [HHb] overshoot was unaffected by hypoxia, but the transient peak [HHb] increased with the reduction in (P < 0.05). Slowed kinetics in hypoxia were positively correlated with increased peak [HHb] in the transient (r2= 0.45; P < 0.05), but poorly related to the [HHb] overshoot. A reduction of spatial heterogeneity in peak [HHb] was inversely correlated with slowed kinetics (r2= 0.49; P < 0.05). These data suggest that aerobic energy provision at the onset of exercise may be limited by the following factors: (i) the absolute ratio (i.e. peak [HHb]) rather than the kinetic ratio (i.e. [HHb] overshoot) of microvascular O 2 delivery to consumption; and (ii) a reduced spatial distribution in the ratio of microvascular O 2 delivery to consumption across the muscle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/expphysiol.2013.073270

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 66

Metadata

Authors
Bowen, T. S., Rossiter, H. B., Benson, A. P., Amano, T., Kondo, N., Kowalchuk, J. M., & Koga, S.
Venue
Experimental Physiology
Publisher
Wiley
Published
2013-08-14
Volume
98
Issue
11
Pages
1585-1596
ISSN
  • 0958-0670 (ISSN-L)
  • 1469-445X
OpenAlex
W2116169906
Cited by
66
References
6
FWCI
17.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Slowed oxygen uptake kinetics in hypoxia correlate with the transient peak and reduced spatial distribution of absolute skeletal muscle deoxygenation. https://app.cochat.ai/papers/10.1113/expphysiol.2013.073270
The paper
Bowen, T. S., Rossiter, H. B., Benson, A. P., Amano, T., Kondo, N., Kowalchuk, J. M., & Koga, S. (2013). Slowed oxygen uptake kinetics in hypoxia correlate with the transient peak and reduced spatial distribution of absolute skeletal muscle deoxygenation. Experimental Physiology. https://doi.org/10.1113/expphysiol.2013.073270

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.