CoChat

The mechano‐gated channel inhibitor GsMTx4 reduces the exercise pressor reflex in decerebrate rats

Open access
Copp, Steven W., Kim, Joyce S., Ruiz‐Velasco, Victor, Kaufman, Marc P. · 2016 · The Journal of Physiology
Cited by 86

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Key points: Mechanical and metabolic stimuli from contracting muscles evoke reflex increases in blood pressure, heart rate and sympathetic nerve activity. Little is known, however, about the nature of the mechano‐gated channels on the thin fibre muscle afferents that contribute to evoke this reflex, termed the exercise pressor reflex. We determined the effect of GsMTx4, an inhibitor of mechano‐gated Piezo channels, on the exercise pressor reflex evoked by intermittent contraction of the triceps surae muscles in decerebrated, unanaesthetized rats. GsMTx4 reduced the pressor, cardioaccelerator and renal sympathetic nerve responses to intermittent contraction but did not reduce the pressor responses to femoral arterial injection of compounds that stimulate the metabolically‐sensitive thin fibre muscle afferents. Expression levels of Piezo2 channels were greater than Piezo1 channels in rat dorsal root ganglia. Our findings suggest that mechanically‐sensitive Piezo proteins contribute to the generation of the mechanical component of the exercise pressor reflex in rats. Mechanical and metabolic stimuli within contracting skeletal muscles evoke reflex autonomic and cardiovascular adjustments. In cats and rats, gadolinium has been used to investigate the role played by the mechanical component of this reflex, termed the exercise pressor reflex. Gadolinium, however, has poor selectivity for mechano‐gated channels and exerts multiple off‐target effects. We tested the hypothesis that GsMTX4, a more selective mechano‐gated channel inhibitor than gadolinium and a particularly potent inhibitor of mechano‐gated Piezo channels, reduced the exercise pressor reflex in decerebrate rats. Injection of 10 μg of GsMTx4 into the arterial supply of the hindlimb reduced the peak pressor (control: 24 ± 5, GsMTx4: 12 ± 5 mmHg,P < 0.01), cardioaccelerator and renal sympathetic nerve responses to tendon stretch, a purely mechanical stimulus, but had no effect on the pressor responses to intra‐arterial injection of α,β‐methylene ATP or lactic acid. Moreover, injection of 10 μg of GsMTx4 into the arterial supply of the hindlimb reduced the peak pressor (control: 24 ± 2, GsMTx4: 14 ± 3 mmHg,P < 0.01), cardioaccelerator and renal sympathetic nerve responses to electrically‐induced intermittent hindlimb muscle contractions. By contrast, injection of 10 μg of GsMTx4 into the jugular vein had no effect on the pressor, cardioaccelerator, or renal sympathetic nerve responses to contraction. Quantitative RT‐PCR and western blot analyses indicated that both Piezo1 and Piezo2 channel isoforms were natively expressed in rat dorsal root ganglia tissue. We conclude that GsMTx4 reduced the exercise pressor reflex in decerebrate rats and that the reduction was attributable, at least in part, to its effect on mechano‐gated Piezo channels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jp271714

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Piezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels

    Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316 · cited 7×

    “Both Piezo1 and Piezo2 isoforms (previously known as FAM38a and FAM38b, respectively) are well-conserved across species (including rodents and humans) and are expressed in a variety of tissues, including DRG tissue (Coste et al. 2010; Delmas et al. 2011; Bagriantsev et al. 2014).”
    BackgroundMethodResultInfluential
  • The Mechanosensitive Ion Channel Piezo1 Is Inhibited by the Peptide GsMTx4

    Bae, C., Sachs, F., & Gottlieb, P. A. (2011) · Biochemistry · doi:10.1021/bi200770q · Cited by 566 · cited 3×

    “GsMTx4 was found to inhibit mechano-gated Piezo1 (Bae et al. 2011; Gottlieb & Sachs, 2012; Bae et al. 2013; Miyamoto et al. 2014) and Piezo2 (Sachs, 2014) channels with at least some degree of selectivity because it did not inhibit mechanically-sensitive TREK-1 channels (Bae et al. 2011).”
    Background
  • Piezo Proteins: Regulators of Mechanosensation and Other Cellular Processes

    Bagriantsev, S. N., Gracheva, E. O., & Gallagher, P. G. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.r114.612697 · Cited by 249 · cited 1×

    “Both Piezo1 and Piezo2 isoforms (previously known as FAM38a and FAM38b, respectively) are well-conserved across species (including rodents and humans) and are expressed in a variety of tissues, including DRG tissue (Coste et al. 2010; Delmas et al. 2011; Bagriantsev et al. 2014).”
    Background

Cited by

See all 86

Metadata

Authors
Copp, S. W., Kim, J. S., Ruiz‐Velasco, V., & Kaufman, M. P.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2016-01-05
Volume
594
Issue
3
Pages
641-655
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2176907467
Cited by
86
References
3
FWCI
7.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.