The variation of hand tremor with force in healthy subjects
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. Total root‐mean‐square (r.m.s.) error over an effectively unrestricted band, and error power spectra from 0·256 to 12·5 c/s were measured for four subjects attempting to maintain fixed forces of 1‐6 Lb. (0·45‐2·72 kg) on a pressure joystick. The subject could see his errors as the deflexion of a cathode ray tube spot. 2. The total r.m.s. error increases linearly with force with a considerable (positive) intercept when the line is extrapolated to zero force. Hence accuracy in the sense (r.m.s. error)/(force) increases with force for this type of control. 3. The rate of increase of total r.m.s. error with force is greater in subjects with prominent tremor peaks in their power spectra at 8‐10 c/s. 4. At each frequency the r.m.s. error per unit bandwidth also increases linearly with force. Except at the very lowest frequencies the rate of increase is greater in subjects with prominent tremor peaks at 8‐10 c/s. This is thought to account for the observation described in paragraph 3. 5. The frequency of the tremor peak near 8‐10 c/s is almost independent of the force exerted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The silent period in a muscle of the human hand
Merton, P. A. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004610 · Cited by 203
Cited by
Optimality principles in sensorimotor control
Todorov, E. (2004) · Nature Neuroscience · doi:10.1038/nn1309 · Cited by 1,746
“Note that motor noise is known to be control-dependent—its magnitude is proportional to muscle activatio”
BackgroundTresch, M. C., Cheung, V. C. K., & d'Avella, A. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00222.2005 · Cited by 838
The contractile properties of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010087 · Cited by 476
Evidence for the Flexible Sensorimotor Strategies Predicted by Optimal Feedback Control
Liu, D., & Todorov, E. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.1110-06.2007 · Cited by 447
“As in previous stochastic optimal control models (Harris and Wolpert, 1998; Todorov, 2002; Todorov and Jordan, 2002b), taking into account the empirically established signaldependent nature of motor noise (Sutton and Sykes, 1967; Schmidt et al., 1979; Todorov, 2002; Hamilton et al., 2004) turns out to be important.”
BackgroundTodorov, E. (2005) · Neural Computation · doi:10.1162/0899766053491887 · Cited by 398
Metadata
- Authors
- Sutton, G. G., & Sykes, K.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1967-08
- Volume
- 191
- Issue
- 3
- Pages
- 699-711
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2151947600
- Cited by
- 70
- References
- 1
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.