The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Identification of cone mechanisms in monkey ganglion cells
Open accessAbstract
1. Blue, green, and red sensitive cone mechanisms have been studied in two types of on‐centre ganglion cells in the Rhesus monkey's retina. 2. One type of cell receives signals from both green and red sensitive cone mechanisms, both of which excite in the centre and inhibit in the periphery of the cell's receptive field. These cells discharge transiently to maintained stimuli of any wave‐length and are called phasic. 3. The second type of cell receives excitatory signals from only one cone mechanism, either blue, green or red sensitive, in the centre, and inhibition from another cone mechanism in the periphery of its receptive field. These cells discharge continuously to maintained stimuli of appropriate wave‐length and are called tonic. 4. Tonic cells outnumber phasic cells although both are found adjacent to one another throughout the retina. Phasic cells are relatively more common toward the periphery and tonic cells relatively more common toward the fovea.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spatial and chromatic interactions in the lateral geniculate body of the rhesus monkey.
Wiesel, T. N., & Hubel, D. H. (1966) · Journal of Neurophysiology · doi:10.1152/jn.1966.29.6.1115 · Cited by 1,275
Change of organization in the receptive fields of the cat's retina during dark adaptation
Barlow, H. B., Fitzhugh, R., & Kuffler, S. W. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005817 · Cited by 778
Visual Pigments of Single Primate Cones
Marks, W. B., Dobelle, W. H., & MacNichol, E. F. (1964) · Science · doi:10.1126/science.143.3611.1181 · Cited by 438
Rod and cone interaction in dark‐adapted monkey ganglion cells
Gouras, P., & Link, K. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007928 · Cited by 205
Self-citationAnalysis and Coding of Color Vision in the Primate Visual System
De Valois, R. L. (1965) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1965.030.01.055 · Cited by 204
The flicker fusion frequency of the blue‐sensitive mechanism of colour vision
Brindley, G. S., Du Croz, J. J., & Rushton, W. A. H. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007879 · Cited by 174
Visual Pigments in Human and Monkey Retinas
Brown, P. K., & Wald, G. (1963) · Nature · doi:10.1038/200037a0 · Cited by 172
Gouras, P. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008328 · Cited by 84
Self-citation
Cited by
Segregation of Form, Color, Movement, and Depth: Anatomy, Physiology, and Perception
Livingstone, M., & Hubel, D. (1988) · Science · doi:10.1126/science.3283936 · Cited by 3,355
Psychophysical evidence for separate channels for the perception of form, color, movement, and depth
Livingstone, M., & Hubel, D. (1987) · The Journal of Neuroscience · doi:10.1523/jneurosci.07-11-03416.1987 · Cited by 1,758
Chromatic mechanisms in lateral geniculate nucleus of macaque.
Derrington, A. M., Krauskopf, J., & Lennie, P. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015499 · Cited by 1,608
Psychophysical evidence for sustained and transient detectors in human vision
Kulikowski, J. J., & Tolhurst, D. J. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010261 · Cited by 690
Functional properties of ganglion cells of the rhesus monkey retina.
De Monasterio, F. M., & Gouras, P. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011086 · Cited by 616
Self-citation
Metadata
- Authors
- Gouras, P.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1968-12
- Volume
- 199
- Issue
- 3
- Pages
- 533-547
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2157300398
- Cited by
- 430
- References
- 8
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.