Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Evaporative water loss in the new‐born baby

Open access
Hey, E. N., Katz, G.·1969·The Journal of Physiology

Abstract

1. Measurements of total evaporative water loss (EWL) were made on sixty‐three premature and full‐term babies 0‐65 days after birth within a closed Perspex chamber under varied environmental conditions by measuring the flow and absolute humidity of air entering and leaving the chamber. Control experiments suggested that the method underestimated loss by about 5%. Measurements of O 2 consumption were made concurrently by recording the volume change of the closed gas circuit. 2. The total basal EWL averaged 10·8 g H 2 O/m 2.hr in infants 2‐10 days old when ambient water vapour pressure (P H 2 O) was 18 mm Hg; basal EWL was correlated with basal metabolic rate at all ages studied and evaporative heat loss accounted for ∼ 23% of basal heat production. 3. Respiratory water loss was measured by detecting the water added to air at 33° C passed across the face of eight infants in a trunk plethysmograph. Respiratory water loss was inversely related to the water vapour content of the inspired air; gas appeared to leave the nose ∼ 95% sat. at 35·6° C. 4. Measurements of total EWL were obtained when humidity was varied and skin loss was calculated by subtracting estimated respiratory loss from total loss; changing P H 2 O from 7 to 25 mm Hg appeared to decrease basal skin water loss by only 1·5 g/m 2.hr. 5. No consistent changes in EWL were obtained when environmental temperature (TE) was varied between 28 and 34° C. Active sweating occurred in infants 0‐10 days old born within 3 weeks of term when TE exceeded 34‐35° C and rectal temperature (TR) rose above 37·2° C. The threshold rectal temperature at which sweating was detected fell significantly in the first 10 days of life; EWL increased two to fourfold when TR rose to between 37·5 and 37·8° C. 6. In infants of less than 215 days post‐conceptual age (term ∼ 268 days) EWL increased less than 50% at TR 37·7‐37·8° C; it is concluded that the sweating mechanism is defective in these infants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1969.sp008711

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 163

Metadata

Authors
Hey, E. N., & Katz, G.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1969-02
Volume
200
Issue
3
Pages
605-619
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1999780863
Cited by
163
References
1
FWCI
11.05
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaporative water loss in the new‐born baby. https://app.cochat.ai/papers/10.1113/jphysiol.1969.sp008711
The paper
Hey, E. N., & Katz, G. (1969). Evaporative water loss in the new‐born baby. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1969.sp008711

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.