The DOI matches its Crossref record.
Regional variations in the visual acuity for interference fringes on the retina
Open accessAbstract
1. The visual acuity of the peripheral retina was measured using both sinusoidal gratings viewed in the usual way and interference fringes formed on the retina directly. 2. It is shown that optical aberrations cause a reduction in peripheral visual acuity for eccentricities of less than 5°. However, the hypothesis that optical defects are a major cause of the well‐known decrease in acuity with eccentricity is rejected. 3. The fringe acuities at various retinal positions are compared with Osterberg's counts of the distribution of cones. It is shown that at eccentricities of less than 2°, resolution approaches the theoretical limits for a mosaic of receptors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A qualitative and quantitative analysis of the human fovea during development
Yuodelis, C., & Hendrickson, A. (1986) · Vision Research · doi:10.1016/0042-6989(86)90143-4 · Cited by 704
Hughes, A. (1977) · Handbook of Sensory Physiology · doi:10.1007/978-3-642-66468-7_11 · Cited by 588
Visual resolution, contrast sensitivity, and the cortical magnification factor
Virsu, V., & Rovamo, J. (1979) · Experimental Brain Research · doi:10.1007/bf00236818 · Cited by 536
Sterling, P., & Laughlin, S. (2015) · doi:10.7551/mitpress/9780262028707.001.0001 · Cited by 482
Cortical magnification factor predicts the photopic contrast sensitivity of peripheral vision
ROVAMO, J., VIRSU, V., & NÄSÄNEN, R. (1978) · Nature · doi:10.1038/271054a0 · Cited by 396
Metadata
- Authors
- Green, D. G.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1970-04
- Volume
- 207
- Issue
- 2
- Pages
- 351-356
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2075846097
- Cited by
- 186
- References
- 0
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Regional variations in the visual acuity for interference fringes on the retina. https://app.cochat.ai/papers/10.1113/jphysiol.1970.sp009065
- The paper
- Green, D. G. (1970). Regional variations in the visual acuity for interference fringes on the retina. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1970.sp009065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.