CoChat

The effects of altering mean pressure, pulse pressure and pulse frequency on the impulse activity in baroreceptor fibres from the aortic arch and right subclavian artery in the rabbit

Open access
James, Jennifer E. Angell · 1971 · The Journal of Physiology
Cited by 109

The DOI matches its Crossref record.

Abstract

1. A method is described for perfusing an isolated preparation of the rabbit aortic arch with independently controlled mean pressure, pulse pressure and pulse frequency. 2. Recordings made from single or few‐fibre preparations from the aortic arch and right subclavian baroreceptor regions show that the number of impulses per second or per cycle in a single fibre is the same during pulsatile perfusion as during non‐pulsatile perfusion if the pressure is above the threshold pressure to non‐pulsatile perfusion during all phases of the pressure cycle. 3. In multi‐fibre recordings the total number of impulses is greater during pulsatile perfusion than during non‐pulsatile perfusion due largely to recruitment of fibres during systole. 4. The relationship between instantaneous impulse frequency and aortic arch pressure during one pressure cycle forms an elliptiform curve. 5. Increasing the pulse pressure increases the ellipse and causes additional recruitment of other fibres during systole, thus augmenting the total impulse activity. 6. Increasing the pulse frequency reduces the number of impulses per cycle for single fibres but produces a small increase in the total impulse frequency in one second period due to recruitment. 7. Increasing the rate of change of pressure by increasing the pulse pressure or pulse frequency produced a small reduction or no change of the threshold pressure. Similarly the ‘cut off’ pressure was elevated in some fibres. 8. At low initial mean pressures, an increment of pressure, at constant pulse pressure and pulse frequency, increases the total impulse activity by increasing the frequency of impulses in single fibres already active during systole and diastole and by additional recruitment of other fibres. At higher mean pressures there is little increase in impulse activity as the maximum frequency of fibres is attained or superseded and there is little recruitment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1971.sp009419

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 109

Metadata

Authors
James, J. E. A.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1971-04
Volume
214
Issue
1
Pages
65-88
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2138343810
Cited by
109
References
0
FWCI
6.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effects of altering mean pressure, pulse pressure and pulse frequency on the impulse activity in baroreceptor fibres from the aortic arch and right subclavian artery in the rabbit. https://app.cochat.ai/papers/10.1113/jphysiol.1971.sp009419
The paper
James, J. E. A. (1971). The effects of altering mean pressure, pulse pressure and pulse frequency on the impulse activity in baroreceptor fibres from the aortic arch and right subclavian artery in the rabbit. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1971.sp009419

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.