The location of the fluid pump in the cornea

Open access
Maurice, D. M.·1972·The Journal of Physiology

Abstract

1. Fluid transport across rabbit corneal tissue has been investigated by observing the movement of fluid interfaces under the microscope, or by mounting the tissue between two chambers and observing the displacement of menisci within capillary tubes. 2. In both cases, the endothelial layer supported on a thin sheet of connective tissue is capable of pumping fluid in a direction out of the cornea, against a head of pressure. The volume of fluid moved may amount to twelve times the thickness of the endothelial cells in an hour. 3. This active fluid movement accounts for the prevention of swelling of the normal corneal stroma. The hypothesis that corneal hydration is regulated by the sodium pump in the epithelial layer is not supported by these experiments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1972.sp009737

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 430

Metadata

Authors
Maurice, D. M.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1972-02
Volume
221
Issue
1
Pages
43-54
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2013955069
Cited by
430
References
0
FWCI
19.35
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The location of the fluid pump in the cornea. https://app.cochat.ai/papers/10.1113/jphysiol.1972.sp009737
The paper
Maurice, D. M. (1972). The location of the fluid pump in the cornea. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1972.sp009737

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.