The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
The location of the fluid pump in the cornea
Open accessAbstract
1. Fluid transport across rabbit corneal tissue has been investigated by observing the movement of fluid interfaces under the microscope, or by mounting the tissue between two chambers and observing the displacement of menisci within capillary tubes. 2. In both cases, the endothelial layer supported on a thin sheet of connective tissue is capable of pumping fluid in a direction out of the cornea, against a head of pressure. The volume of fluid moved may amount to twelve times the thickness of the endothelial cells in an hour. 3. This active fluid movement accounts for the prevention of swelling of the normal corneal stroma. The hypothesis that corneal hydration is regulated by the sodium pump in the epithelial layer is not supported by these experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The permeability to sodium ions of the living rabbit's cornea
Maurice, D. M. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004535 · Cited by 145
Self-citationDavson, H. (1955) · Biochemical Journal · doi:10.1042/bj0590024 · Cited by 144
Harris, J. E., & Nordquist, L. T. (1955) · American Journal of Ophthalmology · doi:10.1016/0002-9394(55)91842-0 · Cited by 126
The imbibition pressure of the corneal stroma
Hedbys, B. O., Mishima, S., & Maurice, D. M. (1963) · Experimental Eye Research · doi:10.1016/s0014-4835(63)80001-9 · Cited by 119
Self-citationStudies on the Living Cornea In Vitro
Donn, A. (1959) · A M A Archives of Ophthalmology · doi:10.1001/archopht.1959.04220050010002 · Cited by 111
Dynamics of water transport in the corneal stroma
Fatt, I. (1968) · Experimental Eye Research · doi:10.1016/s0014-4835(68)80055-7 · Cited by 45
Ion transport in isolated cornea of the rabbit
Green, K. (1965) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1965.209.6.1311 · Cited by 43
Stromal cation binding after inhibition of epithelial transport in the cornea
Green, K. (1970) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1970.218.6.1642 · Cited by 19
Cited by
Proliferative capacity of the corneal endothelium
Joyce, N. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00065-4 · Cited by 611
Waring, G. O., Bourne, W. M., Edelhauser, H. F., & Kenyon, K. R. (1982) · Ophthalmology · doi:10.1016/s0161-6420(82)34746-6 · Cited by 471
Corneal Epithelial Wound Healing
Lu, L., Reinach, P. S., & Kao, W. W.-Y. (2001) · Experimental Biology and Medicine · doi:10.1177/153537020222600711 · Cited by 424
Fuchs endothelial corneal dystrophy: The vicious cycle of Fuchs pathogenesis
Ong Tone, S., Kocaba, V., Böhm, M., Wylegala, A., White, T. L., & Jurkunas, U. V. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100863 · Cited by 284
The Balance between Corneal Transparency and Edema The Proctor Lecture
Edelhauser, H. F. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-1139 · Cited by 282
Metadata
- Authors
- Maurice, D. M.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1972-02
- Volume
- 221
- Issue
- 1
- Pages
- 43-54
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2013955069
- Cited by
- 430
- References
- 8
- FWCI
- 19.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.