The DOI matches its Crossref record.
The effect of diameter on the electrical constants of frog skeletal muscle fibres
Open accessAbstract
1. Electrical constants were determined on isolated single fibres or on fibres from bundles from frog's twitch muscles by analysing the low frequency cable properties. 2. The sarcoplasmic conductivity (Gi) was 5·9 mmho/cm at 20° C, and its temperature coefficient (Q10) was 1·37. 3. The Q10 of the membrane conductance (GM) was 1·49, and that of the membrane capacity (CM) was 1·02. 4. CM increases with diameter (D) in an approximately linear manner: the values were 4·6 μF/cm 2 at D = 50 μ, and 8·5 μF/cm 2 at D = 130 μ. 5. GM also increases with diameter, being 0·21 mmho/cm 2 at D = 50 μ and 0·37 mmho/cm 2 at D = 130 μ. 6. These results suggest that the transverse tubular system contributes substantially to the values of low frequency capacity and conductance measured at the surface membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gating currents and charge movements in excitable membranes
Almers, W. (2006) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0030498 · Cited by 402
Matching dendritic neuron models to experimental data
Rall, W., Burke, R. E., Holmes, W. R., Jack, J. J., Redman, S. J., & Segev, I. (1992) · Physiological Reviews · doi:10.1152/physrev.1992.72.suppl_4.s159 · Cited by 340
Standen, N. B., & Stanfield, P. R. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012379 · Cited by 322
An improved vaseline gap voltage clamp for skeletal muscle fibers.
Hille, B., & Campbell, D. T. (1976) · The Journal of general physiology · doi:10.1085/jgp.67.3.265 · Cited by 311
Clements, J. D., & Redman, S. J. (1989) · The Journal of Physiology · doi:10.1113/jphysiol.1989.sp017485 · Cited by 301
Voltage‐clamp experiments in normal and denervated mammalian skeletal muscle fibres.
Pappone, P. A. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013403 · Cited by 281
Input-output functions of mammalian motoneurons
Powers, R. K., & Binder, M. D. (2007) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0115594 · Cited by 276
Reconstruction of the action potential of frog sartorius muscle
Adrian, R. H., & Peachey, L. D. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010380 · Cited by 274
Properties of the fusion pore that forms during exocytosis of a mast cell secretory vesicle
Spruce, A. E., Breckenridge, L. J., Lee, A. K., & Almers, W. (1990) · Neuron · doi:10.1016/0896-6273(90)90192-i · Cited by 264
Schwartz, L. M., McCleskey, E. W., & Almers, W. (1985) · Nature · doi:10.1038/314747a0 · Cited by 261
A quantitative study of potassium channel kinetics in rat skeletal muscle from 1 to 37 degrees C
Beam, K. G., & Donaldson, P. L. (1983) · The Journal of general physiology · doi:10.1085/jgp.81.4.485 · Cited by 85
Metadata
- Authors
- Hodgkin, A. L., & Nakajima, S.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1972-02
- Volume
- 221
- Issue
- 1
- Pages
- 105-120
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2105468201
- Cited by
- 207
- References
- 0
- FWCI
- 6.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.