Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 714

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

On the regulation of depth and rate of breathing

Open access
Clark, F. J., von Euler, C.·1972·The Journal of Physiology

Abstract

1. The relationships between the depth of a breath and the durations of the inspiratory and expiratory phases have been studied in cat and in man during rebreathing, and in cat using artificial inflations of different magnitudes and timings. 2. In the cat, the apparent volume threshold for termination of inspiration (Hering—Breuer threshold) decreased with time from the onset of the inspiratory phase. 3. Both in rebreathing experiments and with artificially imposed inflations in the cat, the inspiratory duration TI was dependent upon tidal volume VT, and this dependence could be expressed by a hyperbolic relationship of the form (VT‐V0) TI = C where V0 and C are constants. 4. The time course of this ‘Hering—Breuer’ threshold was dependent on intact vagus nerves. After vagotomy the inspiratory duration remained essentially constant with changes in tidal volume produced either by artificial inflation or by the increased respiratory drive due to accumulation of CO 2 during rebreathing. 5. In man during rebreathing, the relation between volume and inspiratory duration typically showed two different characteristics. 1, at tidal volumes up to 1·5–2 times eupnoeic values, inspiratory duration did not change as tidal volume increased in response to increased P CO 2. This range of operation has been designated range 1. 2, as tidal volume increased above this range 1 a second range designated range 2 was observed where inspiratory duration was volume dependent in the same manner as in the cat. 6. In cat under pentobarbitone anaesthesia, a range 1 operation was not seen except after vagotomy. However, under urethane anaesthesia a range 1 plus a range 2 operation could be seen. 7. The differences between cat and man appeared to be largely quantitative rather than qualitative. 8. In both cat and man, expiratory duration was dependent on inspiratory duration, usually with a linear relationship. 9. The experimental results were assembled in the form of an inspiratory characteristic and a timing relationship that serve as a model of the respiratory mechanisms controlling the depth and rate of breathing. The model predicts that the depth and duration of a breath are related in a definite manner fixed by the system characteristics and that ventilation is adjusted by setting the appropriate operating point on these characteristics. The operating point is determined primarily by how quickly lung volume increases, i.e. the rate of increase of inspiratory motor activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1972.sp009797

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 714

Metadata

Authors
Clark, F. J., & von Euler, C.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1972-04
Volume
222
Issue
2
Pages
267-295
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1973440483
Cited by
714
References
10
FWCI
13.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.