The DOI matches its Crossref record.
Nervous activity of afferent cardiac sympathetic fibres with atrial and ventricular endings
Open accessAbstract
1. We recorded the electrical activity of single afferent cardiac fibres isolated from the third and fourth left thoracic sympathetic rami communicantes of anaesthetized cats. Their conduction velocities ranged from 12 to 32 m/sec. 2. The endings of each fibre were localized to one cardiac chamber by mechanical probing of the opened heart performed at the end of the experiment. 3. The impulse activity was spontaneous and, in fibres with atrial or ventricular endings, it was in phase with a particular atrial or ventricular event. 4. This nervous activity increased during increases in pressure occurring in the chamber where the endings were located. Conversely, decreases in pressure were accompanied by decreased nervous discharge. 5. In some experiments the left coronary artery was perfused at different flows and pressures. Brief decreases or increases in coronary flow and pressure decreased or increased, respectively, the discharge of fibres with atrial or ventricular endings. Fibres were excited by intracoronary injections of veratridine. 6. Cessation of coronary pump flow increased the discharge of fibres with atrial or ventricular endings only when myocardial ischaemia was accompanied by signs of heart failure. 7. These afferent cardiac sympathetic fibres which provide the spinal cord with continuous specific information on cardiac events are likely to contribute to the neural control of circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Self-citationMalik, M. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00275.x · Cited by 850
La Rovere, M. T., Specchia, G., Mortara, A., & Schwartz, P. J. (1988) · Circulation · doi:10.1161/01.cir.78.4.816 · Cited by 631
Self-citationSchwartz, P. J., Vanoli, E., Stramba-Badiale, M., De Ferrari, G. M., Billman, G. E., & Foreman, R. D. (1988) · Circulation · doi:10.1161/01.cir.78.4.969 · Cited by 576
Self-citation
Metadata
- Authors
- Malliani, A., Recordati, G., & Schwartz, P. J.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1973-03
- Volume
- 229
- Issue
- 2
- Pages
- 457-469
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2152719385
- Cited by
- 289
- References
- 0
- FWCI
- 10.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nervous activity of afferent cardiac sympathetic fibres with atrial and ventricular endings. https://app.cochat.ai/papers/10.1113/jphysiol.1973.sp010147
- The paper
- Malliani, A., Recordati, G., & Schwartz, P. J. (1973). Nervous activity of afferent cardiac sympathetic fibres with atrial and ventricular endings. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1973.sp010147
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.