The DOI matches its Crossref record.
Intracellular pH of snail neurones measured with a new pH‐sensitive glass micro‐electrode
Open accessAbstract
1. The construction and properties of a new design of pH‐sensitive micro‐electrode are described. The electrodes are very durable, and have a recessed configuration so that only the extreme tip, which can be as small as 1 μm in diameter, needs to enter the cell. 2. The average intracellular pH in thirty‐two snail neurones was 7·4. This was not in accord with a passive distribution of H+ ions across the cell membrane. 3. Changing membrane potential or external pH had only slow effects on internal pH. 4. Removing external K had no effect, and removing external Na had only slow and variable effects on intracellular pH. 5. Anoxia, azide and DNP all caused a slow fall in internal pH. 6. External CO 2 caused large and rapid decreases in internal pH, which external bicarbonate appeared to offset slowly. Injected bicarbonate increased internal pH. 7. The size of the pH changes caused by CO 2 suggested a minimum intracellular buffering power of 25 m‐equiv H+/unit pH per l., equivalent to that of 150 m M Tris maleate, pH 7·4. 8. External ammonia caused a large and rapid increase in internal pH, while the injection of ammonium ions had the opposite effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(1989) · PubMed · Cited by 1,639
Intracellular pH transients in squid giant axons caused by CO2, NH3, and metabolic inhibitors.
Boron, W. F., & De Weer, P. (1976) · The Journal of general physiology · doi:10.1085/jgp.67.1.91 · Cited by 919
Boron, W. F., & Boulpaep, E. L. (1983) · The Journal of general physiology · doi:10.1085/jgp.81.1.53 · Cited by 566
The regulation and modulation of pH in the nervous system
Chesler, M. (1990) · Progress in Neurobiology · doi:10.1016/0301-0082(90)90034-e · Cited by 454
pH regulation and proton signalling by glial cells
Deitmer, J. W., & Rose, C. R. (1996) · Progress in Neurobiology · doi:10.1016/0301-0082(95)00039-9 · Cited by 296
Metadata
- Authors
- Thomas, R. C.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1974-04
- Volume
- 238
- Issue
- 1
- Pages
- 159-180
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2054928936
- Cited by
- 348
- References
- 0
- FWCI
- 16.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracellular pH of snail neurones measured with a new pH‐sensitive glass micro‐electrode. https://app.cochat.ai/papers/10.1113/jphysiol.1974.sp010516
- The paper
- Thomas, R. C. (1974). Intracellular pH of snail neurones measured with a new pH‐sensitive glass micro‐electrode. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1974.sp010516
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.