Role of cations, anions and carbonic anhydrase in fluid transport across rabbit corneal endothelium

Open access
Fischbarg, J., Lim, J. J.·1974·The Journal of Physiology

Abstract

1. A small electrical potential difference (541 ± 48 μV, aqueous side negative) across rabbit corneal endothelium has been recently found. Its dependence on ambient [Na+], [K+], [H+] and metabolic and specific inhibitors was examined. 2. Changes in concentration of the ions above either were known or were presently shown to affect the rate of fluid transport across this preparation (normal value: 5·2 ± 0·4 μl./hr.cm 2). Ionic concentration changes were also found here to influence potential difference in the same way as fluid transport. In the cases tested, the effects on both fluid transport and potential difference were reversible. 3. Fluid transport and potential difference were both decreased or abolished in absence of Na+, K+ and HCO 3−, and when [H+] was decreased. Fluid transport and potential difference were saturable functions of [HCO 3−] and half‐saturation occurred in both cases at about 13 m M‐HCO 3−. The potential difference was also a saturable function of [Na+] (half‐saturation around 15 m M). There was a pH optimum for potential difference in the range 7·4–7·6. Lower pH values decreases the potential difference and the fluid transport, and a small (−100 μV) reversed potential was observed in the range of 5·3–5·5. 4. Total replacement of Cl− by HCO 3− or SO 42− produced no impairment on either fluid transport or potential difference. 5. Carbonic anhydrase inhibitors (ethoxyzolamide 10−5 or 10−4 M and benzolamide 10−3 M) produced a 40–60% decrease in the rate of fluid pumping. In contrast, ethoxyzolamide 10−4 M or acetazolamide 10−3 M did not produce any change in the potential difference. NaCN and Na iodoacetate (both 2 m M) eliminated the potential difference in 1‐1·5 hr while in controls it lasted for 5‐6 hr. 6. Ouabain (10−5 M) abolished the potential difference in less than 10 sec when added to the aqueous side, which suggests the existence of an electrogenic pump. This extremely fast time transient can be accounted for by the accessibility and simple geometry of the present monocellular layer. Ouabain abolished also the reversed potential difference observed at low pH. 7. The data are interpreted in terms of a scheme similar to that advanced for other epithelia and in which (a) H+ would be pumped into the intercellular spaces, while Na+ and CO 2 would enter into the cells, and (b) Na+ would be subsequently pumped into the aqueous humour, producing as a result the fluid movement observed. The actual origin of the potential difference is further discussed in terms of two contrasting possibilities: (i) one or more electrogenic pumps, and (ii) a neutral pump which would create a diffusion potential across ‘leaky’ intercellular junctions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1974.sp010676

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 195

Metadata

Authors
Fischbarg, J., & Lim, J. J.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1974-09
Volume
241
Issue
3
Pages
647-675
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2032268647
Cited by
195
References
1
FWCI
2.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Role of cations, anions and carbonic anhydrase in fluid transport across rabbit corneal endothelium. https://app.cochat.ai/papers/10.1113/jphysiol.1974.sp010676
The paper
Fischbarg, J., & Lim, J. J. (1974). Role of cations, anions and carbonic anhydrase in fluid transport across rabbit corneal endothelium. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1974.sp010676

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.