Baroreflex inhibition of the human sinus node: importance of stimulus intensity, duration, and rate of pressure change.
Open accessThe DOI matches its Crossref record.
Abstract
1. Carotid baroreceptors were stimulated with electronically controlled neck suction in five healthy young men and pulse interval prolongation was measured. Timing of the onset of stimuli in relation to cardiac activity was held constant, and stimulus intensity, duration, and dP/dt were varied independently. 2. In the subjects studied, sinus node responses to neck suction were proportional to dP/dt. However, variations of stimulus dP/dt within or above the normal range for arterial dP/dt did not influence the magnitude of integrated baroreflex responses, or the earliest portion of baroreflex sinus node inhibition. 3. Carotid baroreflex responses were linear over a wide range which extended beyond the normal range for human systolic arterial pressures. 4. Saturation of the carotid baroreceptor‐cardiac reflex occurred at distending pressures of about 160 mmHg. 5. The average baroreflex responses of the group studied were highly reproducible over time. 6. Baroreflex gain correlated very strongly with base line pulse interval. 7. The magnitude of baroreflex responses increased linearly with the duration of carotid sinus distension and reached a maximum level with stimuli lasting 0‐5 sec or more. 8. The results demonstrate that carotid sinus transfer characteristics can be measured in normal man, and that human response patterns are strikingly similar to those observed earlier in experimental animals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
La Rovere, M. T., Specchia, G., Mortara, A., & Schwartz, P. J. (1988) · Circulation · doi:10.1161/01.cir.78.4.816 · Cited by 631
Parati, G., Di Rienzo, M., Bertinieri, G., Pomidossi, G., Casadei, R., Groppelli, A., Pedotti, A., Zanchetti, A., & Mancia, G. (1988) · Hypertension · doi:10.1161/01.hyp.12.2.214 · Cited by 616
Arterial Baroreflexes in Humans
Mancia, G., & Mark, A. L. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020320 · Cited by 292
Prognostic value of baroreflex sensitivity testing after acute myocardial infarction.
Farrell, T. G., Odemuyiwa, O., Bashir, Y., Cripps, T. R., Malik, M., Ward, D. E., & Camm, A. J. (1992) · Heart · doi:10.1136/hrt.67.2.129 · Cited by 269
Phase relationship between normal human respiration and baroreflex responsiveness.
Eckberg, D. L., Kifle, Y. T., & Roberts, V. L. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013338 · Cited by 233
Self-citation
Metadata
- Authors
- Eckberg, D. L.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1977-08
- Volume
- 269
- Issue
- 3
- Pages
- 561-577
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2052642362
- Cited by
- 96
- References
- 0
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Baroreflex inhibition of the human sinus node: importance of stimulus intensity, duration, and rate of pressure change. https://app.cochat.ai/papers/10.1113/jphysiol.1977.sp011915
- The paper
- Eckberg, D. L. (1977). Baroreflex inhibition of the human sinus node: importance of stimulus intensity, duration, and rate of pressure change. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1977.sp011915
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.