The DOI matches its Crossref record.
Intracellular pH in early Xenopus embryos: its effect on current flow between blastomeres.
Open accessAbstract
1. Electrophysiological techniques were used to monitor the flow of electric current from one cell to the next in Xenopus laevis embryos between the 4‐cell and early blastula stages of development. Intracellular pH and blastocoel pH were determined using pH‐sensitive micro‐electrodes. 2. The resting intracellular pH was 7.74+/‐0.02 (S.E. of mean, n = 29); there were no systematic differences between developmental stages. Blastocoel cavity pH was 8.4+/‐0.06 (S.E. of mean, n = 10). The intracellular buffer value was 18 m‐equiv. H+/pH unit per litre. 3. In embryos treated with bicarbonate buffered Holtfreter solution equilibrated with 100% CO2 the intracellular pH fell to 6.3+/‐0.17 (S.D., n = 8). The membrane potential fell and the input resistance increased. The size of the effect on membrane potential and input resistance varied. 4. From the 32‐cell stage onwards current flow from one cell to the next was abolished when the intracellular pH fell to below 6.5; the effect was rapid in onset and completely reversible. At cleavage stages of development lowering intracellular pH with CO2 had no effect on current flow from cell to cell. 5. The relationship between intracellular pH and current flow from cell to cell was sigmoid and covered between 0.2 and 0.4 pH units. The pH at which current flow was completely abolished ranged from 6.85 to 6.4. 6. Alterations in extraembryonic pH over the range 5.8‐7.5 had no effect on any parameter measured. 7. We conclude that lowering the intracellular pH increases the resistance of both non‐junctional junctional membranes. The data do not allow us to extract the pH junctional conductance relationship. 8. Variations in intracellular pH may provide a useful tool for the study of the functional role of direct cell to cell communication in both adult organs and early embryos.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Emerging issues of connexin channels: biophysics fills the gap
L. Harris, A. (2001) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583501003705 · Cited by 800
Regulation of intracellular pH in eukaryotic cells
Madshus, I. H. (1988) · Biochemical Journal · doi:10.1042/bj2500001 · Cited by 635
Gap Junctional Conductance Is a Simple and Sensitive Function of Intracellular p H
Spray, D. C., Harris, A. L., & Bennett, M. V. L. (1981) · Science · doi:10.1126/science.6779379 · Cited by 482
Warner, A. E., Guthrie, S. C., & Gilula, N. B. (1984) · Nature · doi:10.1038/311127a0 · Cited by 433
Self-citationLevin, M., Thorlin, T., Robinson, K. R., Nogi, T., & Mercola, M. (2002) · Cell · doi:10.1016/s0092-8674(02)00939-x · Cited by 403
Single-channel currents of an intercellular junction
Neyton, J., & Trautmann, A. (1985) · Nature · doi:10.1038/317331a0 · Cited by 344
Five-hour half-life of mouse liver gap-junction protein.
Fallon, R. F., & Goodenough, D. A. (1981) · The Journal of cell biology · doi:10.1083/jcb.90.2.521 · Cited by 327
Clusters of Coupled Neuroblasts in Embryonic Neocortex
Lo Turco, J. J., & Kriegstein, A. R. (1991) · Science · doi:10.1126/science.1850552 · Cited by 314
Lasater, E. M., & Dowling, J. E. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.9.3025 · Cited by 299
pH regulation and proton signalling by glial cells
Deitmer, J. W., & Rose, C. R. (1996) · Progress in Neurobiology · doi:10.1016/0301-0082(95)00039-9 · Cited by 296
Adams, D. S., Robinson, K. R., Fukumoto, T., Yuan, S., Albertson, R. C., Yelick, P., Kuo, L., McSweeney, M., & Levin, M. (2006) · Development · doi:10.1242/dev.02341 · Cited by 269
Chemical gating of gap junction channels
Peracchia, C. (2004) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2003.10.020 · Cited by 260
Electrical coupling between cells in islets of langerhans from mouse
Eddlestone, G. T., Gonçalves, A., Bangham, J. A., & Rojas, E. (1984) · The Journal of Membrane Biology · doi:10.1007/bf01871095 · Cited by 137
Electron spin changes during general anesthesia in Drosophila
Turin, L., Skoulakis, E. M. C., & Horsfield, A. P. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1404387111 · Cited by 71
“Considering that the intracellular pH of every cell in the animal falls by ∼1 pH unit during 100% CO2 exposure (68), it is remarkable that has no influence at all on either signal (Fig.”
BackgroundSelf-citationIntercellular Communication in Arthropods
Berdan, R. C. (1987) · Cell-to-Cell Communication · doi:10.1007/978-1-4613-1917-7_10 · Cited by 12
Metadata
- Authors
- Turin, L., & Warner, A. E.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1980-03
- Volume
- 300
- Issue
- 1
- Pages
- 489-504
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2078578060
- Cited by
- 214
- References
- 0
- FWCI
- 8.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.